Annotated start, layer and toolchange G-code¶
This is the stock profile, reproduced verbatim
Everything below is Prusa's own PrusaSlicer profile for the Core One INDX on firmware 6.9.0 — not a customization. If you are on 6.9.0 this is what you already have, before you change anything.
That is the reason to read it. The values are the shipped defaults rather than anyone's tuning, so understanding what each block does tells you what your machine is actually doing on every print, and gives you a baseline to diff your own changes against.
The command behavior is verified against the Prusa firmware source. The profile itself changes between firmware releases, so check the version above against yours — the 6.6.3 profile differed from this one in several places.
Written for 6.9.0; firmware has since reached 8.0.0
Firmware 6.9.1 went stable on 25 September 2026, 6.9.2 followed on 7 October, 7.0.0
on 15 October, 7.0.1 on 19 October and 8.0.0 on 22 October. The blocks on this page
are still the 6.9.0 profile, and they have deliberately not been edited to match
later releases. Prusa's profile bundle 2.5.10, of 17 September, ships these blocks
unchanged. So does 2.5.11, which reached Prusa's profile repository on 2 October, a
week after 6.9.1: all five INDX blocks are identical to 2.5.10's, and the M115
line still declares 6.9.0. Bundle 2.5.12, of 15 October, is the first to change
them, and 2.5.13, of 22 October, changes them again; see the note below. If the
profile in your slicer differs from what is shown here, yours is the current one.
The firmware side has been checked against the public source, comparing
the 6.9.0 and 6.9.1 release tags.
No command annotated here changed meaning, and M574 still has no handler. Two
behave differently underneath:
G427probes cooler, with the temperature now capped in firmware, and allows more attempts at a valid reading when it probes the offset sensor. That attempt count is compiled in. It is not thePargument, which still sets how many probes are averaged, and the handler that readsRandPis unchanged.- The parking routine behind
G27lifts Z faster when moving away from the bed, and there is a fix to howW3picks which tool's park position to use, which the release notes do not mention.
6.9.2 changes none of this. Comparing the 6.9.1 and 6.9.2 release tags, it adds the printer's PVA and BVOH filament presets, which the 6.9.1 notes announced and its build left out, and touches no G-code handler.
None of 7.0.0, 7.0.1 or 8.0.0 has been checked the same way. Prusa had published the
source of none of them on GitHub by 25 October, so every command annotation here is
verified only through 6.9.2. Two entries in the 7.0.0
release notes sit close to this
page, and both are marked as coming from earlier releases. The faster Z lift when
parking, marked 6.9.1 and 6.10.2, is the G27 change 6.9.1 already shipped.
Improved Nozzle Wiper cleaning, marked 6.10.1, comes from the XL firmware line, where
6.10.1
introduced the Nozzle Wiper as XL+ hardware. A comment in that release's
hardware menu source
gives the wiper's internal name as the nozzle cleaner lite, and in its
build options
that is a separate feature from the INDX's cleaning station and is not built for
the INDX. Neither entry is new in 7.0.0. The one new entry that names the cleaner,
filament load and unload positions now taking the calibrated nozzle cleaner offset,
concerns the firmware's own load and unload moves; whether it changes anything the
G12 lines below do cannot be checked until the source is out.
Two entries in the 8.0.0 notes,
both new, touch this page as well. The first gives M204 an F parameter, a
filament acceleration limit that the notes say is enabled by default. The profile's
own M204 lines set only S, and nothing in bundle 2.5.13 issues M204 F, so
whatever limit 8.0.0 applies comes from the firmware, not from the profile. The
second slows flexible filament less than before during nozzle cleaning. That is the
firmware's own cleaning motion: none of the G12 lines below passes a speed.
TODO(verify): what exactly M204 F limits, and its default; the 8.0.0 notes state
neither, and its source is unpublished.
Bundles 2.5.12 and 2.5.13 changed three of these blocks after this page was written
Prusa's profile bundle 2.5.12, committed on 15 October 2026, the day firmware 7.0.0 came out, lists a reworked INDX tool change script and a new firmware version notice in its changelog. Comparing the file with 2.5.11:
- Start: only the
M115line changed. It now declares 6.9.2, asM115 U6.9.2+16336, rather than the 6.9.0 shown below, and not 7.0.0. - Tool change: changed in three ways, none of them in the flush pattern.
- The
G27park line and four filament moves around the swap are now fenced by;EXCLUDE_E_STARTand;EXCLUDE_E_ENDcomment lines: the push that locks a primed tool, the push before the wipe-tower moves, and, on each path, a new move that puts back whatG27 Rretracted at park. PrusaSlicer's G-code processor reads those tags only from comment lines and leaves the extruder moves between them out of its filament-use tally (PrusaSlicer 2.9.6 source). In 2.5.11 the only pair present, around the lock push, lacked the semicolon, so it was not a comment and the processor did not act on it. - The deretract before the flush is split in two for a tool already primed:
first the length
G27 Rtook back at park, then the rest. The total is unchanged; only the first part falls inside the tags. A tool not yet primed keeps the single deretract. The wipe-tower path splits its deretract the same way. - The retract after the flush on the purge-station path no longer adds the
extra
+ 0.04; see the note on it in the start block below. The start block's own retract still adds it.
- The
- Before layer change, after layer change and end: unchanged.
Bundle 2.5.13 followed on 22 October, the day firmware 8.0.0 came out. Its changelog lists an updated INDX layer G-code script and another firmware version notice, and comparing the file with 2.5.12 bears that out:
- Start: again only the
M115line. It now declares 7.0.1, the point release of 19 October, asM115 U7.0.1+16905, and not 8.0.0. - After layer change: each of the eight PET-family tests in the dock-fan section
gains a trailing
.*, so the pattern reads(PET|CPE|PCTG).*. That lets PETG match again: bundles 2.5.0 to 2.5.6 tested(PETG|PET), which matched it, and the 2.5.7 rewrite dropped it; the after-layer-change section below explains why. - Before layer change, tool change and end: unchanged from 2.5.12.
The blocks below are still the 2.5.11 text. The tool change excerpts no longer match 2.5.12 or later, and the PET-family test in the after-layer-change excerpt no longer matches 2.5.13. They have not been rewritten here: this page reproduces one profile verbatim and annotates it, and a new reproduction would be a new revision of the page, not an edit to it.
What this is¶
Five blocks, covering the whole print lifecycle:
| Block | Runs | Does |
|---|---|---|
| Start | Once, before the print | Preflight checks, homing, tool calibration, heat soak, mesh bed leveling, clean and prime |
| Before layer change | Every layer | Resets the extruder, tapers acceleration with height |
| After layer change | Every layer | Dock fan control, on layers 1 and 3 only |
| Tool change | Every tool change | Park, swap, purge or wipe, resume |
| End | Once, at the end | Cool down, park, disable |
They are not independent. The start block sets globals the other four read, and one line at the very end of the start block silently changes what the first tool change does. That coupling is called out where it happens.
Start G-code¶
Globals and the probe temperature¶
{
global retract_toolchange = 8;
global tool_init = (0,0,0,0,0,0,0,0);
global used_tools = 0 ;
global low_temp_types = "PLA|PVA|BVOH|FLEX|TPU|TPE|PVB";
}
; number of used tools
{if is_extruder_used[0]}{used_tools = used_tools + 1}{endif}
{if is_extruder_used[1]}{used_tools = used_tools + 1}{endif}
{if is_extruder_used[2]}{used_tools = used_tools + 1}{endif}
{if is_extruder_used[3]}{used_tools = used_tools + 1}{endif}
{if is_extruder_used[4]}{used_tools = used_tools + 1}{endif}
{if is_extruder_used[5]}{used_tools = used_tools + 1}{endif}
{if is_extruder_used[6]}{used_tools = used_tools + 1}{endif}
{if is_extruder_used[7]}{used_tools = used_tools + 1}{endif}
{local probe_temp = "" + ((filament_notes[initial_tool]=~/.*MBL160.*/) ? 160 : (filament_notes[initial_tool]=~/.*HT_MBL10.*/) ? (first_layer_temperature[initial_tool] - 10) : (filament_type[initial_tool] == "PC" or filament_type[initial_tool] == "PA") ? (first_layer_temperature[initial_tool] - 55) : (filament_type[initial_tool] == "FLEX") ? 170 : (filament_type[initial_tool]=~/.*PET.*/) ? 170 : 170) + "";}
None of this emits G-code. It runs in the slicer and sets up state the rest of the profile reads.
The four globals persist across every block in the print, which is the only reason the layer and toolchange blocks can see them:
retract_toolchange— extra retraction used when parking a tool, referenced later byG27 Rand by the deretract length on the way back in.tool_init— an eight-slot array, one per tool, all starting at zero. A tool's slot flips to1the first time it has been cleaned and primed. The tool change block branches on this; see the coupling note at the end of the start block.used_tools— a count, built by the eight lines that follow. The after-layer-change block gates its whole dock-fan section onused_tools > 1, so a single-tool print skips it entirely.low_temp_types— a regex alternation of the materials treated as low-temperature. Defined here, used only in the after-layer-change block. If you remove this line, that block breaks with an undefined variable, which is not obvious from reading either block on its own.
The probe temperature is a chain of conditionals picking the nozzle temperature the
machine will hold while probing the bed. It reads, in order: a filament-note override,
a second note-based override relative to first-layer temperature, a lower temperature
for PC and PA, a fixed value for FLEX, a fixed value for anything PET-ish, and finally a
default. The "" + ... + "" wrapper coerces the result to a string so it can be
substituted into M109 later.
The interesting part is why it exists: probing wants the nozzle hot enough not to be dimensionally odd, but cool enough not to ooze onto the sheet while the loadcell is trying to read contact. Oozing during probing is a known failure mode — see oozing spoils bed probing.
Preflight checks¶
M862.3 P "COREONEINDX" ; printer model check
M862.5 P2 ; g-code level check
M862.6 P"Input shaper" ; FW feature check
M862.6 P"INDX lock" ; FW feature check
M115 U6.9.0+16311
M591 S0 ; disable stuck detection
M555 X{(min(print_bed_max[0], first_layer_print_min[0] + 32) - 32)} Y{(max(0, first_layer_print_min[1]) - 4)} W{((min(print_bed_max[0], max(first_layer_print_min[0] + 32, first_layer_print_max[0])))) - ((min(print_bed_max[0], first_layer_print_min[0] + 32) - 32))} H{((first_layer_print_max[1])) - ((max(0, first_layer_print_min[1]) - 4))}
; inform about nozzle diameter
{if (is_extruder_used[0])}M862.1 T0 P{nozzle_diameter[0]} A{(filament_abrasive[0] ? 1 : 0)} F{(nozzle_high_flow[0] ? 1 : 0)}{endif}
{if (is_extruder_used[1])}M862.1 T1 P{nozzle_diameter[1]} A{(filament_abrasive[1] ? 1 : 0)} F{(nozzle_high_flow[1] ? 1 : 0)}{endif}
{if (is_extruder_used[2])}M862.1 T2 P{nozzle_diameter[2]} A{(filament_abrasive[2] ? 1 : 0)} F{(nozzle_high_flow[2] ? 1 : 0)}{endif}
{if (is_extruder_used[3])}M862.1 T3 P{nozzle_diameter[3]} A{(filament_abrasive[3] ? 1 : 0)} F{(nozzle_high_flow[3] ? 1 : 0)}{endif}
{if (is_extruder_used[4])}M862.1 T4 P{nozzle_diameter[4]} A{(filament_abrasive[4] ? 1 : 0)} F{(nozzle_high_flow[4] ? 1 : 0)}{endif}
{if (is_extruder_used[5])}M862.1 T5 P{nozzle_diameter[5]} A{(filament_abrasive[5] ? 1 : 0)} F{(nozzle_high_flow[5] ? 1 : 0)}{endif}
{if (is_extruder_used[6])}M862.1 T6 P{nozzle_diameter[6]} A{(filament_abrasive[6] ? 1 : 0)} F{(nozzle_high_flow[6] ? 1 : 0)}{endif}
{if (is_extruder_used[7])}M862.1 T7 P{nozzle_diameter[7]} A{(filament_abrasive[7] ? 1 : 0)} F{(nozzle_high_flow[7] ? 1 : 0)}{endif}
G90 ; use absolute coordinates
M83 ; extruder relative mode
The M862.x family are compatibility gates. They compare what the file expects against
what the machine actually is, and stop the print rather than let it fail expensively
later:
M862.3 P"COREONEINDX"— printer model. Sliced for the wrong machine, this is where it stops.M862.5 P2— G-code dialect level.M862.6 P"<feature>"— a named firmware feature must be present. Two are required here: input shaping, and the INDX lock.M862.1— per-tool nozzle declaration, repeated once per used tool:Tthe tool,Pits diameter,Awhether the assigned filament is abrasive,Fwhether the nozzle is high-flow. This is what lets the firmware object when an abrasive filament is about to be run through a nozzle not marked as suitable for it — see nozzle hardness for why that flag matters on this machine.
M115 U… declares the firmware version the file was generated for.
M591 S0 disables the filament stuck-detection feature for the print. That detection
works by reading extrusion back-pressure through the load cell — the same sensor Prusa
has said will calibrate pressure advance in a future firmware. Why the INDX profile
switches it off at print start is not established.
M555 declares the print area, derived from the first layer's bounding box with margin.
The firmware uses it to know which part of the bed matters — most visibly, it is what
mesh bed leveling probes rather than probing the whole sheet.
G90 / M83 set absolute positioning for motion and relative for the extruder. Every
E value after this point is a delta, not a target.
Homing, tool preparation and calibration¶
M140 S{first_layer_bed_temperature[initial_tool]} ; set bed temp
{if chamber_minimal_temperature[initial_tool] == 0}
M141 S{chamber_temperature[initial_tool]} ; set nominal chamber temp
{endif}
; Home XY
G28 XY
; Pick tool for Z homing
{if is_extruder_used[0]}T0 S1 L2 D0
{elsif is_extruder_used[1]}T1 S1 L2 D0
{elsif is_extruder_used[2]}T2 S1 L2 D0
{elsif is_extruder_used[3]}T3 S1 L2 D0
{elsif is_extruder_used[4]}T4 S1 L2 D0
{elsif is_extruder_used[5]}T5 S1 L2 D0
{elsif is_extruder_used[6]}T6 S1 L2 D0
{elsif is_extruder_used[7]}T7 S1 L2 D0
{endif}
M104 S120
; Home Z
G28 Z
G0 Z40 F10000
M190 R{first_layer_bed_temperature[initial_tool]} ; wait for bed temp
; try picking tools used in print
G1 F10000
Bed and chamber setpoints go out first so heating overlaps everything that follows.
M140 and M141 set targets without waiting; M190 later is the one that blocks.
The chamber line is conditional. If the filament declares a minimum chamber temperature it is skipped here, because a dedicated chamber-soak section further down handles that case instead.
G28 XY homes the two axes that do not need a tool fitted. Z homing does, because Z is
found by touching the nozzle to the bed — so a tool is picked first. The elsif chain
picks the lowest-numbered used tool, whichever that is.
M104 S120 sets a modest nozzle target before Z homing. Warm enough that any residue on
the tip is soft rather than a hard lump under the probe, cool enough not to ooze while
the machine works.
After homing, G0 Z40 drops the bed clear and M190 R… waits for the bed to reach
temperature. This is the longest single wait in the whole startup.
{local perimeter_flow_rate = 1.0 * (external_perimeter_speed > 0 ? external_perimeter_speed : (perimeter_speed > 0 ? perimeter_speed : 100)) * (layer_height * (external_perimeter_extrusion_width - layer_height) + 3.14159 * (layer_height/2) * (layer_height/2))}
{if (is_extruder_used[0] and filament_type[0] != "FLEX")}M574 S0 V35 T{temperature[0]} F{ (filament_max_volumetric_speed[0] > 0 ? min(perimeter_flow_rate, filament_max_volumetric_speed[0]) : perimeter_flow_rate ) / (3.14159 / 4 * filament_diameter[0] * filament_diameter[0]) }{endif}
(repeated once per tool, S0 through S7 — only the first is shown here)
perimeter_flow_rate is computed once and reused by all eight lines. It is the
volumetric flow implied by the external perimeter settings: speed multiplied by the
cross-sectional area of an extrusion, modeled as a rectangle with semicircular ends.
The fallback chain means it degrades to perimeter speed, then to a constant, rather
than producing zero if a speed is unset.
Each M574 line then converts that volumetric figure into a linear filament feedrate by
dividing by the filament's cross-sectional area, capped by the material's maximum
volumetric speed where one is set. FLEX is excluded.
Note the unit. Every input above is in mm per second, so F is emitted in mm per second
of filament. A Marlin F is always mm per minute. Whatever consumes this is not using
the standard feedrate convention, which is further sign that M574 is a custom command
carrying its own.
M574 has no handler in published firmware — and probably not finished
No Prusa firmware whose source is published, the INDX's up to 6.9.2 included, has a
handler for M574. The printer logs Unknown command:, answers ok, and carries
on: eight ignored lines per print, one per used non-FLEX tool. Nothing breaks. That
is derived from the firmware source — no capture from a real machine appears to
exist publicly, and Prusa develops privately, so it establishes that the firmware
you run ignores it if that is 6.9.2 or earlier, not that no handler exists
anywhere. For 7.0.0, 7.0.1 and 8.0.0, whose source is unpublished, it is unchecked.
There is no commit to find either. The line ships out-of-band in Prusa's vendor
profile bundle, first appearing in
PrusaResearch 2.5.0 on
26 June 2026 and rewritten in 2.5.7 on 20 August. It is INDX-exclusive. A sibling
M573 R — a literal bare flag, not an unrendered placeholder — sits directly beneath
M572 in the filament start G-code and is equally absent from the firmware.
On 13 August 2026 Prusa
announced
a flow-dependent pressure advance model whose parameters the load cell measures
before every print, plus extrusion-aware acceleration limits. No release date, no
firmware version, and no G-code named. M574 carries per tool a temperature and
the external-perimeter extrusion rate — not the print's peak — which is the shape of
input that work would need, and the profiles predate the announcement by seven weeks.
No source connects the two, and the payload fits the acceleration-limit half at
least as well as the calibration half.
Firmware 8.0.0 has since added a filament acceleration limit, enabled by default,
but its release notes give it as
M204 F, not M574, and tie it neither to the announcement nor to M574. Bundle
2.5.13, published the same day, still carries the eight M574 lines.
One practical warning: M574 means endstop configuration in RepRap and
RepRapFirmware, so almost everything a search returns describes a Duet.
TODO(verify): what M574 and M573 R are for, and what S, V, T and F mean.
S as a tool index and T as a temperature are inferred from the call site — hold
that loosely, since Marlin's own convention is the reverse. The fixed V35 has no
established meaning and is deliberately not guessed at.
G427 R2 P3 ; Calibrate all used and mapped tools
T{initial_tool} S1 L0 D0
G427 runs the full tool offset calibration for every mapped tool: it works out which
physical tools the print needs, calibrates each in XYZ, and writes the results to
runtime variables and EEPROM. If the firmware has no record of which tools the print
uses, G427 falls back to calibrating every enabled tool
(firmware source,
unchanged from 6.9.0). One open feature request says this is the case for prints a
host such as OctoPrint sends over USB or serial, so even a print that uses one tool
calibrates them all
(#5508).
Its two parameters are both about accuracy. R is millimeters of random jitter applied
to X and Y while Z-probing each tool, which stops every probe landing on exactly the
same spot. P is how many Z probes to take per point and average. So R2 P3 means
jitter by two, average three.
This is the step that fails on machines with a bad offset sensor — see tool offset calibration fails.
T{initial_tool} S1 L0 D0 then picks the tool the print actually starts with.
Chamber soak, heat soak and mesh bed leveling¶
{if chamber_minimal_temperature[initial_tool] != 0}
; Min chamber temp section
M104 S0
M140 S115 ; set bed temp for chamber heating
G1 Z10 F720 ; set bed position
G1 X242 Y0 F4800 ; set print head position
M191 S{chamber_minimal_temperature[initial_tool]} ; wait for minimal chamber temp
M141 S{chamber_temperature[initial_tool]} ; set nominal chamber temp
M140 S{first_layer_bed_temperature[initial_tool]} ; set bed temp
{endif}
{if first_layer_bed_temperature[initial_tool] <= 60}M106 S70{endif}
G0 Z40 F10000
M104 S{if is_nil(idle_temperature[initial_tool])}100{else}{idle_temperature[initial_tool]}{endif}
M190 R{first_layer_bed_temperature[initial_tool]} ; wait for bed temp
M107
G29 G ; absorb heat
M109 S{probe_temp} ; wait for temp
The chamber section is the counterpart to the conditional near the top: it only runs for
filaments that declare a minimum chamber temperature. The technique is to drive the bed
hot and park the head low and to one side, using the bed as a chamber heater, then wait
on M191 for the chamber to come up before restoring the real bed target.
Outside that, a cool bed target gets some part-cooling fan to help it settle, the nozzle
drops to an idle temperature while waiting, and M107 turns the fan off before probing.
G29 G is a heat-soak step — it holds while the machine comes to thermal equilibrium,
which matters because probing a cold frame and printing on a hot one gives different
answers.
M109 S{probe_temp} then brings the nozzle to the probing temperature worked out at the
very top of the file, and waits for it.
;
; MBL
;
M84 E ; turn off E motor
G29 P1 ; invalidate mbl & probe print area
;G29 P1 X150 Y0 W100 H20 C ; probe near purge place
G29 P3.2 ; interpolate mbl probes
G29 P3.13 ; extrapolate mbl outside probe area
G29 A ; activate mbl
G0 Z1 ; add Z clearance
M569 S0 E ; set spreadcycle mode for extruder
G92 E0 ; reset extruder position
Mesh bed leveling, in stages. M84 E de-energizes the extruder motor first so it
cannot creep and disturb a reading. G29 P1 throws away any existing mesh and probes
the print area — the area declared by M555 earlier. P3.2 interpolates between the
probed points, P3.13 extrapolates the mesh outward past the probed region so travel
outside the print area still has a defined Z, and G29 A activates the result.
The commented-out line is an alternative that probes near the purge area instead.
M569 S0 E puts the extruder driver into spreadcycle rather than stealthchop — less
quiet, more predictable torque, which is what you want for an extruder rather than a
gantry axis.
Clean and prime the initial tool¶
;-------Clean and prime initial tool------
{
local speed_tc = min(travel_speed, 350.0) * 60;
local deretract_length = 1.6;
local target_temp = first_layer_temperature[initial_tool];
local eject_temp = max(160,target_temp - 60);
local filament_area = 3.14 * filament_diameter[initial_tool] * filament_diameter[initial_tool] / 4.0;
local purge_mm = 12 / filament_area;
local purge_speed_fast = 60.0 * min(6,max(1.5,0.6*filament_max_volumetric_speed[initial_tool]/filament_area));
local purge_speed_slow = 60.0 * min(3,max(1.5,0.3*filament_max_volumetric_speed[initial_tool]/filament_area));
local tc_deretract_speed = 60.0 * min(20,max(5,deretract_speed[initial_tool]));
}
M83
G1 F{speed_tc}
M204 S7000
M104 S{eject_temp+15}
G12 S90 ; enter cleaner
M109 C{eject_temp} ; Skip residency
M104 S{target_temp + 5}
G12 S30 ; eject poop
M106 S{255 / 100 * max_fan_speed[initial_tool]}
M906 P1 ; Set extruder current
M109 C{target_temp}
M104 S{target_temp}
G1 E{deretract_length} F{tc_deretract_speed}
G91 ; use relative coordinates
M83 ; extruder relative mode
M572 S0.0 ; Disable PressureAdvance
;FLUSH_START
G1 X-0.2 E{0.15 * purge_mm} F{0.20 / (0.15 * purge_mm) * purge_speed_slow}
G1 X0.40 E{0.30 * purge_mm} F{0.40 / (0.30 * purge_mm) * purge_speed_slow}
G1 Y-0.5 E{0.10 * purge_mm} F{0.50 / (0.10 * purge_mm) * purge_speed_slow}
G1 Y-0.5 E{0.10 * purge_mm} F{0.50 / (0.10 * purge_mm) * purge_speed_fast}
G1 X-0.4 E{0.20 * purge_mm} F{0.40 / (0.20 * purge_mm) * purge_speed_fast}
G1 Y1.00 E{0.18 * purge_mm} F{1.00 / (0.18 * purge_mm) * purge_speed_fast}
G1 X0.20 E{0.05 * purge_mm} F{0.20 / (0.05 * purge_mm) * purge_speed_fast}
G1 Y0.20 E{0.02 * purge_mm} F{0.20 / (0.02 * purge_mm) * purge_speed_slow}
;FLUSH_END
M400
M906 P0 ; Revert extruder current
G1 Y0 E-{retract_length[initial_tool] + 0.04} F{retract_speed[initial_tool] * 60}
{e_retracted[initial_tool] = retract_length[initial_tool] + retract_restart_extra_toolchange[initial_tool]}
G1 Y5 F{speed_tc}
{tool_init[initial_tool] = 1}
G90 ; use absolute coordinates
M83 ; extruder relative mode
G12 S91 ; Exit cleaning station
G0 Z1.2 ; Lift
G4 S0
M221 S100 ; set flow to 100%
This section deliberately mirrors the tool change block, so the first tool starts the print in the same state a swapped-in tool would.
The cleaning station is driven by G12 with a sub-code. S90 enters it, S30
ejects the accumulated purge material, S91 exits. Everything between S90 and S91
happens with the head parked at the station rather than over the bed.
The two-stage temperature approach is the part worth copying. eject_temp is set
well below the print temperature. The nozzle is brought down to that before ejecting,
because material that has cooled somewhat detaches from the tip as a solid pellet rather
than stringing. Only after the eject does it come up to printing temperature.
M109 C rather than M109 S is what makes this practical. The C form waits for the
temperature to be reached but skips the residency period a normal M109 S enforces, so
each of these waits costs seconds rather than tens of seconds. The profile's own comment
says exactly that.
M906 P1 … M906 P0 raises the extruder motor current for the purge and puts it
back afterwards, because pushing a large volume quickly asks more of the motor than
printing does.
The flush pattern is eight short moves in X and Y, each extruding a stated fraction
of purge_mm. The feedrates are computed rather than fixed: each is distance ÷ extrusion
÷ speed, which keeps the head's linear speed matched to the extrusion so the purge lays
down consistently instead of stretching or bunching. The pattern alternates direction to
break the strand up.
M572 S0.0 disables pressure advance for the purge — its whole purpose is to smooth
transitions, which is unwanted when you are deliberately pushing a fixed volume.
M400 waits for the move queue to drain before the current is reverted, so the change
does not land mid-move.
The retract after the flush takes back slightly more filament than the line after it
records as retracted in e_retracted, and nothing in the shipped profile pushes the
difference back out. Up to bundle 2.5.11 the purge-station path of the tool change block
did the same. That is deliberate. Asked on Prusa's profile repository why the extra is
there, a Prusa profile maintainer replied on 7 October 2026 that it relieves a little
more pressure after the flush, and was added together with switching pressure advance
off for it. The same reply said Prusa is considering removing it after more testing
(issue 49).
Bundle 2.5.12, of 15 October, has since dropped it from the tool change block but kept
it in this start block, and 2.5.13 leaves it where 2.5.12 put it; the issue itself had
no further reply and was still open on 25 October.
The last interesting line is {tool_init[initial_tool] = 1}
That marks the starting tool as already cleaned and primed. Nothing in this block uses it — the tool change block does, and it changes behavior in two ways.
A tool whose tool_init is still 0 gets a fixed deretract length instead of the
computed one, and is forced down the purge-station path even if a wipe tower is
configured. That is deliberate: a tool that has never been primed needs a proper
purge, and a wipe tower is not the place to do it.
So this single assignment is the difference between the first tool change behaving like a normal one and behaving like a first-time initialization. If you rewrite this section, carry that line across.
Before layer change¶
;BEFORE_LAYER_CHANGE
G92 E0.0
;[layer_z]
{if layer_z > 150}
M201 X{interpolate_table(layer_z, (0,7000), (150,7000), (200,4500), (270,2000))} Y{interpolate_table(layer_z, (0,7000), (150,7000), (200,4500), (270,2000))}
{endif}
G92 E0.0 resets the extruder's position counter each layer, keeping the numbers small.
The rest is the most interesting idea in the profile: acceleration is reduced as the
print gets taller. interpolate_table takes the current layer height and interpolates
between the given points, so X and Y acceleration stays flat up to a threshold and then
falls away steadily toward the top of the build volume.
The reasoning is mechanical. A tall part is a lever — the taller it gets, the more a given acceleration deflects the top of it, and the more the machine's own frame flexes. Reducing acceleration with height trades print time for accuracy exactly where the trade is worth making, and leaves short prints untouched.
The {if layer_z > 150} guard means nothing is emitted at all below the flat region, so
a short print carries no extra G-code.
This connects to a wider community view that stock accelerations on this machine sit high for its motors, and to diagonal banding, where extrusion and motion artifacts have to be told apart.
After layer change¶
The excerpt in this section is the 2.5.11 text, which 2.5.12 left alone. Bundle 2.5.13 changes its PET-family test; see below.
;AFTER_LAYER_CHANGE
;[layer_z]
; dock fan control
{if layer_num == 1 or layer_num == 3}
M106 P6 S0 ; dock fan off (baseline)
{if used_tools > 1}
;PET-family (PET/PETG/*-CF...)/CPE/PCTG - dock fan 100 from 3rd layer
{if layer_num == 3 and ((is_extruder_used[0] and filament_type[0]=~/(PET|CPE|PCTG)/) or ...)}
M106 P6 S100
{endif}
;low-temp materials - dock fan 100% (S255) from 1st layer (uses global low_temp_types)
{if (is_extruder_used[0] and one_of(filament_type[0], ~low_temp_types)) or ...}
M106 P6 S255
{endif} ; PLA wins by order
{endif}
{endif}
(the per-tool conditions are elided — each expands to all eight tools)
M106 P6 addresses the dock fan, not the part-cooling fan. The P index selects a
fan, and index 6 is the dock fan, which exists only on INDX builds. A bare M106 S…
elsewhere in the profile is the part fan.
The logic only fires on layers 1 and 3, and only when more than one tool is in use — a single-tool print has nothing docked to cool.
Tracing it through:
- Layer 1 — baseline off, then the PET branch is skipped because it requires layer 3, so only the low-temperature branch can fire. Low-temperature materials get full dock fan from the very first layer.
- Layer 3 — baseline off, then the PET branch may set partial dock fan, and the low-temperature branch may then overwrite it with full.
That ordering is intentional, and the profile's own comment records it: PLA wins by order. Where a plate mixes both, the low-temperature setting is the one that survives.
From bundle 2.5.7 through 2.5.12 the PET branch never matched PETG. PrusaSlicer's
=~ succeeds only when the pattern matches the whole string, not part of it
(PrusaSlicer 2.9.6 source),
so (PET|CPE|PCTG) as shown above matches a filament type of exactly PET, CPE or PCTG.
Every live PET-family INDX filament preset in 2.5.12, Generic PETG and Prusament PETG,
PETG V0 and PETG Carbon Fiber, has the type PETG. On a multi-tool print whose only
PET-family material was PETG, the profile therefore never switched the dock fan on
unless a low-temperature material was also on the plate, whatever its comment says.
This was a regression: the script in bundles 2.5.0 to
2.5.6
tested (PETG|PET), which does match PETG, and the
2.5.7
rewrite of 20 August replaced it. Bundle 2.5.13 appends .* to the pattern, and from
then on PETG matches again. This is read from the profile and the slicer source, not
observed on a machine. The probe-temperature line in the start block was never affected:
its PET test already has a wildcard on both sides.
S100 is not 100 percent
M106 takes a PWM value from 0 to 255, so S255 is full and S100 is about 39%.
The comment on the PET branch reads "dock fan 100", meaning the raw value — it is
easy to read that as a percentage and conclude the two branches do the same thing.
They do not.
The reason low-temperature materials want dock cooling earliest is that they soften nearest to ambient, so a tool sitting in its dock beside a heated chamber is most at risk of the filament in it going soft.
Tool change¶
The excerpts in this section are the 2.5.11 text. Bundle 2.5.12 changes this block in several places; the note at the top of this page lists them.
G1 F{speed_tc}
M204 S7000
G27 W3 Z{travel_max_lift[current_extruder]} P2 R{retract_toolchange} V{tc_retract_speed/60} A{travel_slope[current_extruder]}
P0 S1 L0 D0
T{next_extruder} S1 L0 D0
M104 S{eject_temp+15}
G12 S90 ; enter cleaner
G0 Z{layer_z + 0.8} ; Lift
M109 C{eject_temp} ; Skip residency
M104 S{target_temp + 5}
The setup block above this (elided for length) computes the same locals as the prime section, plus a few branches: a zero configured purge falls back to a fixed volume, an explicit flush volume or speed overrides the computed one, FLEX gets its own retract and deretract speeds, and — as described above — an uninitialized tool gets a fixed deretract length and is forced down the purge-station path.
There is also a first-layer override: if the layer is at or below first-layer height, the target temperature becomes the first-layer temperature rather than the normal one.
G27 is the park, and its parameters are worth reading carefully:
| Parameter | Meaning |
|---|---|
W3 |
Use the predefined tool park position (toolchangers only) |
Z… |
Z component of the park position |
P2 |
Z action: relative move by Z |
R… |
Distance to retract during the parking moves |
V… |
Retraction feedrate, independent of the move feedrate |
A… |
Do the Z move in parallel with XY, at this angle, until target Z is reached |
The A parameter is a nice touch — instead of lifting and then traveling, the head
climbs on a slope while it moves, which is faster.
P0 S1 L0 D0 then drops the current tool in its dock, and T{next_extruder} S1 L0 D0
picks up the new one.
G12 S30 ; eject poop
M106 S{255 / 100 * max_fan_speed[next_extruder]}
M906 P1 ; Set extruder current
M109 C{target_temp}
M104 S{target_temp}
G1 E{deretract_length} F{tc_deretract_speed}
G91 ; use relative coordinates
M83 ; extruder relative mode
M572 S0.0 ; Disable PressureAdvance
;FLUSH_START
G1 X-0.2 E{0} F{1200}
G1 X0.40 E{0.15 * purge_mm} F{0.40 / (0.15 * purge_mm) * purge_speed_slow}
G1 Y-1.20 E{0.35 * purge_mm} F{1.20 / (0.35 * purge_mm) * purge_speed_fast}
G1 X-0.4 E{0.20 * purge_mm} F{0.40 / (0.20 * purge_mm) * purge_speed_fast}
G1 Y1.20 E{0.25 * purge_mm} F{1.20 / (0.25 * purge_mm) * purge_speed_fast}
G1 X0.20 E{0.05 * purge_mm} F{0.20 / (0.05 * purge_mm) * purge_speed_fast}
;FLUSH_END
M400
M906 P0 ; Revert extruder current
G1 Y0 E-{retract_length[next_extruder] + 0.04} F{retract_speed[next_extruder] * 60}
G1 Y5 F{speed_tc}
The purge-station path, taken when there is no wipe tower or when the incoming tool has never been primed. It is the same shape as the prime sequence in the start block: eject cold, fan on, current up, come to temperature, deretract, flush in a computed pattern, retract, current back.
The wipe-tower path instead issues a series of G750 moves, which run the wipe-tower
sequence with the tower's own geometry, and skips the station entirely.
G90 ; use absolute coordinates
M83 ; extruder relative mode
G12 S91 ; Exit cleaning station
G0 Z{layer_z + 1.0} ; Lift
G4 S0
Both lifts in this block are layer-relative
G0 Z{layer_z + 0.8} on the way in and G0 Z{layer_z + 1.0} on the way out are both
computed from the current layer height. Neither consults the height of anything
already finished on the plate. The park itself uses P2, a relative Z move, rather
than P0, which is the option documented as "raise to at least Z above print".
On an ordinary print every object rises together, so the current layer is the tallest thing on the bed and this is fine. On a sequential print it is not: a finished object can stand far above the layer being printed elsewhere, and a travel computed from the current layer passes straight through it.
That is the mechanism behind toolhead collides with finished parts. Reading this block makes it concrete in a way the community bug report could not: the clearance-aware option exists in the firmware and this profile does not use it.
This is not a suggested fix. Whether P0 would actually resolve it depends on
what the firmware means by "above print" — whether it tracks completed object heights
or only the current one — which has not been established. It is the first thing to
investigate, not a change to make blind.
TODO(verify): whether G27 P0 accounts for completed objects on a sequential print,
and whether the two G0 Z{layer_z + …} lifts can be made clearance-aware.
End G-code¶
{if layer_z < max_print_height}G1 Z{z_offset+min(max_layer_z+1, max_print_height)} F720 ; Move print head up{endif}
; turn off extruder heaters
{if is_extruder_used[0]}M104 T0 S0{endif}
{if is_extruder_used[1]}M104 T1 S0{endif}
{if is_extruder_used[2]}M104 T2 S0{endif}
{if is_extruder_used[3]}M104 T3 S0{endif}
{if is_extruder_used[4]}M104 T4 S0{endif}
{if is_extruder_used[5]}M104 T5 S0{endif}
{if is_extruder_used[6]}M104 T6 S0{endif}
{if is_extruder_used[7]}M104 T7 S0{endif}
M140 S0 ; turn off heatbed
M141 S0 ; disable chamber control
M107 ; turn off fan
M106 P6 S0 ; turn off dock fan
P0 S1 ; park tool
G1 X242 Y205 F10200 ; park
G4 ; wait
M572 S0 ; reset PA
M221 S100 ; reset flow percentage
M84 X Y E ; disable motors
M77 ; stop print timer
; max_layer_z = [max_layer_z]
The bed drops away first, guarded so it cannot try to exceed the machine's maximum.
Heaters are turned off per tool rather than globally — M104 T<n> S0 addresses a
specific tool, and only tools actually used are touched. Then bed, chamber, part fan and
dock fan.
P0 S1 returns the tool to its dock. Leaving a tool on the head at the end would mean
starting the next print with an unexpected state.
G4 with no argument waits for the queue to drain. M572 S0 and M221 S100 reset
pressure advance and flow so a later print does not inherit them — worth doing because
both persist in firmware across prints.
M84 X Y E disables the X, Y and extruder motors but deliberately leaves Z energized, so
the bed holds its position rather than sagging.
Command reference¶
Behavior verified against the Prusa firmware source unless marked otherwise.
| Command | What it does |
|---|---|
M862.1 T P A F |
Declare per-tool nozzle: tool, diameter, abrasive flag, high-flow flag |
M862.3 P"model" |
Printer model gate |
M862.5 P<n> |
G-code dialect level gate |
M862.6 P"feature" |
Required firmware feature gate |
M115 U<ver> |
Declare the firmware version the file targets |
M555 X Y W H |
Declare the print area |
M591 S<0\|1> |
Filament stuck detection off/on |
G28 XY / G28 Z |
Home the named axes |
T<n> S L D |
Select a tool |
P0 S1 [L D] |
Park the current tool in its dock |
G27 W Z P R V A |
Park the head; see the table above for parameters |
G427 R P |
Tool offset calibration; R jitter mm, P probes averaged |
G29 G |
Heat-soak / absorb heat |
G29 P1 |
Invalidate the mesh and probe the print area |
G29 P3.2 |
Interpolate between probed points |
G29 P3.13 |
Extrapolate the mesh beyond the probed area |
G29 A |
Activate the mesh |
G12 S90 |
Enter the cleaning station |
G12 S30 |
Eject accumulated purge material |
G12 S91 |
Exit the cleaning station |
G750 Y F A |
Wipe-tower move |
M104 S / M104 T<n> S |
Set nozzle target, current tool or a named one, no wait |
M109 S |
Set nozzle target and wait, including residency |
M109 C |
Set nozzle target and wait, skipping residency |
M140 S / M190 R |
Bed target / wait for bed |
M141 S / M191 S |
Chamber target / wait for chamber |
M106 S |
Part-cooling fan, PWM 0–255 |
M106 P6 S |
Dock fan, PWM 0–255 |
M107 |
Part-cooling fan off |
M204 S |
Set acceleration |
M204 F |
Filament acceleration limit, new in 8.0.0 and on by default per its release notes; not issued by the profile, and not checked against source |
M201 X Y |
Set per-axis maximum acceleration |
M221 S |
Flow percentage |
M572 S |
Pressure advance; S0 disables |
M569 S0 E |
Extruder driver to spreadcycle |
M906 P<0\|1> |
Extruder current: raised for purging, reverted after |
M400 |
Wait for the move queue to drain |
M84 [axes] |
Disable the named motors |
M77 |
Stop the print timer |
M262 P B |
IO expander pin direction — B0 output, B1 input |
M264 P B |
IO expander pin level — B0 low, non-zero high |
M574 S V T F |
No handler in published firmware source, through 6.9.2; logged as unknown and skipped |
Verification¶
measured — this is Prusa's shipped profile for firmware 6.9.0, reproduced verbatim
rather than reconstructed, and every command's behavior was checked against the
firmware handler that implements it rather than assumed from standard Marlin.
That provenance is what earns the tier. These are not one owner's settings that happened to work; they are the vendor's defaults, which every INDX on this firmware starts with. The values are therefore general in a way the rest of this site's numbers are not — which is also why they appear here at all, when the site otherwise withholds print settings until someone has verified them on hardware.
Where a command's meaning could not be established it is marked as such rather than
guessed. M574 is the only one in that state, and the distinction matters: its absence
from the firmware is now established to the same standard as the other commands'
presence — checked against the v6.9.0 release tag and every object in the public
repository's history, with positive controls. What it was intended to do is still
unknown, and is flagged in place rather than reconstructed. Prusa's August 2026
announcement of load-cell pressure advance calibration is first-party and cited, but
nothing published connects it to this command; the page keeps the two apart deliberately.
M262 and M264 deserve a note. They are frequently described as chamber-light
commands, and the profile they came from labeled them that way. They are not: the
firmware implements them as generic I2C GPIO expander operations — configure a pin
direction, write a pin level. What a given pin controls is whatever the owner has wired
to it. Anything you read that treats them as a lighting command is describing a
convention, not the command.
What is not verified: whether these defaults are good. They are what Prusa ships, which makes them authoritative as a description and says nothing about whether a given value is optimal for your filament or your part. Several are actively disputed by owners — stock temperatures and accelerations both come up on the forum as running high for this toolhead. Reproducing a default is not endorsing it.
Nor is the profile static. It changes across firmware releases: the 6.6.3 version had a
misspelled variable in the probe-temperature expression, used a different offset for PC
and PA, omitted the low_temp_types global that the after-layer-change block depends on,
and included chamber-light commands this one drops. If your firmware differs from the
version in the front matter, expect differences. The profile also moves between bundles
on its own schedule: 2.5.12 reworked the tool change block and declares 6.9.2, not the
7.0.0 released the same day, and 2.5.13 widened the dock-fan test to take in PETG and
declares 7.0.1, not the 8.0.0 released the same day, as the note at the top describes.
Related¶
- Toolhead collides with finished parts — the tool change block's layer-relative lifts, in context
- Oozing spoils bed probing — why the probe temperature is computed the way it is
- Tool offset calibration fails — what
happens when
G427cannot complete - Blobs dragged into the print — the purge and cleaning behavior these blocks drive