Skip to content

Oozing spoils bed probing and tool calibration

Summary

Filament that oozes while the machine is probing or calibrating puts material where the machine is trying to take a measurement, and the measurement fails. Owners have hit this during bed probing and during tool offset calibration, with more than one filament type. There are several contributing causes and they are worth separating, because the one with the best first-hand evidence — a dirty offset sensor window — is also the easiest to fix and the least likely to be what you suspect first.

Detail

Two different measurements get spoiled by ooze, and they fail differently:

  • Bed probing. Material accumulates on the nozzle tip before or during the probing pass, so contact is detected early or inconsistently. Owners report probing leaving visible deposits on the sheet.
  • Tool offset calibration. Ooze interferes with the nozzle being sensed properly against the offset sensor, and calibration fails. One owner reports this failing on every tool after swapping nozzle sizes around, and having to unload all filament, calibrate, then reload.

Start here: clean the offset sensor window

The resolution that actually closed the main thread on this was cleaning the sensor window on each nozzle. The owner reported the swabs coming away visibly black even though they did not believe they had touched the windows, and a test print working afterwards. This costs a few minutes and it is the highest-value thing to check.

Which sensor that window belongs to is disputed. Replies in the same thread call it a temperature window, and the silicone sock page, which holds that the eddy-current offset sensor has no optical window at all, leaves the identification open. The cleaning result stands either way.

Do not clean the sensor window with IPA

The advice relayed in the thread is to use soapy water and a cotton swab rather than isopropyl alcohol, on the grounds that IPA is too aggressive for that window. Provenance is worth stating plainly: this was described as a vendor recommendation circulating on Discord, and the person relaying it said openly that they could not point to an official source. Soapy water is the low-risk choice either way, so prefer it — but treat the reason as unconfirmed.

TODO(verify): whether the vendor has published an official cleaning procedure for the offset sensor window.

Clean it, but do not polish it

A later caution in the same thread is worth heeding: the sensor face is meant to be matte, and should not end up shiny or reflective. Be sparing. The goal is to lift filament debris off it, not to bring up a shine.

One caveat on that advice — the owner giving it describes the sensor as infrared, whereas the offset sensor is elsewhere described as eddy-current based. Those are different sensing principles and it is not clear which component is meant. The practical instruction is sound either way: remove the debris, stop there.

Dry the filament

Suggested early and repeatedly for PETG in particular: moisture makes filament stringy and encourages it to stick to the nozzle. This is standard practice rather than an INDX-specific finding, and it was offered as a first guess rather than a confirmed cause in these threads — but the INDX is reported to be more moisture-sensitive than the Nextruder it replaces, so it is worth ruling out before chasing anything more complicated.

Residue the pre-calibration clean leaves behind

provisional — a single report. Before tool offset calibration measures a tool it purges, cools and wipes that tool's nozzle, so whatever the wipe misses is on the nozzle when it is measured. One INDX owner, filing in October against 6.9.2 and 7.0.0, found PETG left on the nozzle ahead of probing now and then on 6.9.0 and often on the two later releases, and traced a Z offset that came out too high to it (#5567). Going back to 6.9.0 helped a good deal but did not cure it. They blame the worsening on the lower calibration temperature that arrived with 6.9.1, at which leftover PETG is fully hard. Neither the 7.0.0 nor the 8.0.0 notes list a change to that temperature or to the order of the clean. Their only items on the clean itself, improved wiper cleaning in 7.0.0 and a smaller slowdown for flexible filament in 8.0.0, say nothing about PETG left on the nozzle. Other owners report the same residue and put it down to the order of the clean or to its temperature; that evidence is collected under Residue left by the clean before calibration on blobs dragged into the print.

The probe temperature may not be the one you expect

There is a reported firmware and slicer behavior where the temperature used for pre-print bed probing is derived from the filament assigned to tool 1, not from the tool actually doing the probing. If a high-temperature material is assigned to T1, everything probes hot and oozes, regardless of what is loaded elsewhere.

The reported workaround is elegant if it holds: it is enough to declare a low-temperature filament in T1 in the slicer — the physical filament does not have to be there — which would explain why jobs sliced from profiles that assume a low-temperature material never showed the problem. On the stock profile this site reproduces, though, the rule is keyed to the print's initial tool rather than to T1 — see the PC section below before relying on it. There is also a start-G-code approach that forces the probing temperature before the mesh bed leveling block, by replacing the generated temperature command with a fixed one.

TODO(verify): the probing temperature to force, and the exact G-code command and argument to use. Also TODO(verify): the reduction one owner used successfully on a non-INDX Core One for the same symptom, quoted as a range rather than a single figure. No temperature is published on this page until someone has confirmed it on hardware.

Two further reported details in this area, worth knowing before you go hunting: a slicer configuration update corrected how that temperature is worked out, for most materials — though one engineering material still probes hot; and the temperature used for tool offset calibration is fixed in firmware and cannot be changed from G-code, so this workaround does not help that failure mode. The firmware source bears out only part of that second detail. At the v6.9.1 tag the calibration sets its own probing temperatures, at or below a built-in ceiling, and the calibration command G427 reads no temperature argument, so through 6.9.2 no G-code can raise the probing temperature above that ceiling. Below it, the Z-probe temperature follows the preheat value of the filament loaded in that tool, and M865 can change that value, and the temperature the tool purges at, for a user-defined or ad hoc filament, though not for a built-in preset. The XY-probe temperature is fixed. So the calibration temperature is capped rather than fixed: G-code can lower the Z-probe temperature, but cannot raise it or move the XY one (see Verification). An October bug report, which holds that the lower calibration temperature makes leftover PETG worse, suggests among its fixes a temperature parameter for the calibration command, or a temperature that follows the filament as the bed-probing one does (#5567). There is also a sibling slicer trap in which the bed temperature follows T1 in the same way.

The engineering material is PC. A second owner hit this with PC Blend and described it from the other end: probing ran hot enough to ooze onto the sheet and fail leveling, and lowering the nozzle temperature by hand on the next attempt cured it outright. That moved "at least one engineering material still probes hot" off a single report and gave it a name, and it has not stayed with one owner since. Two further owners in the same thread, another in a separate thread, and a firmware issue all describe PC Blend failing bed probing until the temperature comes down.

Where the temperature comes from. There is no dedicated probing-temperature field in the slicer, but there is a rule. The stock printer start G-code works out the probing temperature from the filament of the print's initial tool — the first tool the print actually uses — and gives PC and PA a case of their own: a fixed offset below the first-layer temperature. The annotated profile reproduces that expression in its section on globals and the probe temperature — see annotated profile G-code. It is the rule these owners keep running into.

Initial tool, not T1. That expression reads the filament of initial_tool, which is not the T1 behavior reported further up. The two select the same filament only when a print starts on T1. On a print that starts on another tool they point at different presets — so on this profile, declaring a low-temperature filament in T1 will not help a print that begins on T3; the filament to look at is the one your print starts with. Whether the earlier T1 report describes an older profile or a different machine state is not established.

No firmware release so far lists a change here. The 6.9.1 beta lowered the temperature used for tool offset calibration — a different step, and one that firmware controls. The bed-probing temperature comes from the slicer profile, so owners on the beta still see PC Blend probe hot, and the bug report filed against the beta is still open, with no reply from Prusa. The stable 6.9.1, published 2026-09-25, lists a gantry-squaring wizard and a homing fix, and nothing about probing temperature. Its notes also do not repeat the beta's calibration changes, but the stable carries them all the same: in the firmware repository it is the beta tag plus 15 further commits, none of which touches tool offset calibration. That comes from the release history, not the notes. 6.9.2, released 2026-10-07, changes nothing here either: on the INDX it is the stable 6.9.1 plus the PVA and BVOH filament presets that the 6.9.1 notes announced but left out (compare). Firmware 7.0.0, dated 15 October 2026 on Prusa's downloads page, lists nothing on probing temperature either, and nor does 8.0.0, dated 22 October, which fits the value coming from the slicer profile. On 18 October a further commenter on the bug report hit the failure as soon as they tried PC Blend, without naming a machine or a firmware version. No owner has yet reported how PC Blend probes on stable 6.9.1, 6.9.2, 7.0.0, 7.0.1 or 8.0.0.

Adjusting it. One owner widened the PC offset in the printer's start G-code and the failures stopped. The catch, which they pointed out themselves, is that a printer configuration update replaces the start G-code, so the edit has to be redone after each one. The same expression also checks the initial tool's filament notes for an override marker before it ever reaches the PC case, which suggests a per-filament route that would survive those updates — but that is a reading of the profile, not something an owner has reported testing. And the slicer's own oozing-prevention option did not help, so reaching for it first will cost you a print. The owner who filed the PC Blend bug report suggests a stopgap that touches no file: as soon as bed probing starts, turn the nozzle temperature down from the Tune menu. It is the hand-lowered temperature described above, timed to the probing, and it has to be repeated on every print.

TODO(verify): these accounts state the temperature PC probed at, the lower ones that worked, and the adjusted offset. None of them is published here. Forum posts and a bug report are not the hardware confirmation this page requires before a temperature goes on it — but they are leads, and they are the same figure the marker above is asking for.

When leveling fails and retries

provisional for the owner reports — a few of them, and on their face they do not agree. The firmware source, below, matches each to the step that failed. Once bed leveling has failed on a fouled nozzle, do not count on the retry starting from a clean one. A feature request describes the head moving over to the wiper and then going back to the bed for another attempt without scrubbing the nozzle. An owner on the 6.9.1 beta, in the nozzle cleaning thread, found the tool left parked in the silicone wiper block, out of reach for cleaning by hand; the print went ahead only after several retries. Two other owners there describe something different: a retry that heats, purges and wipes the nozzle again even after it has been cleaned by hand, fouling it enough to fail once more. One of them was also on a 6.9.1 build, and allows that their own wiper setting or a loadcell fault may be to blame; the other gives no version, and neither does the feature request. So firmware version does not explain the difference, and those two posts do not say whether bed leveling or tool offset calibration was the step failing.

Two steps, two retries. Read against the firmware source, the accounts stop conflicting: they describe different steps. When bed leveling cannot get a reading, the printer parks the head at its park position, which the code places inside the nozzle cleaner area, asks whether to retry, and on a yes leaves the cleaner and probes again with no cleaning in between. That is the feature request and the beta owner. When tool offset calibration fails during a print, the printer parks the head at the front with the bed lowered, where the nozzle can be reached, and on Retry runs the per-tool preparation again — heat, purge, cool, wipe — before it probes. After a failed XY scan that is the failing tool alone; after a failed Z probe the retry restarts calibration from the first tool, so every tool is purged again. That is the re-fouling the other two owners describe, and it happens however well the nozzle was just cleaned. Both paths take the same steps in 6.9.0, the 6.9.1 beta and stable 6.9.1 (in the preparation, the beta changed only the temperature it cools to), which is why version did not separate the reports. That holds for Prusa's own builds; the owner on a 6.9.1 build posted before the stable release and did not say which build it was. The bed-leveling code does have a branch that wipes and retries, but it belongs to a probe-cleanup pass that the stock INDX start G-code does not call.

In practice: a failed bed leveling will not clean the nozzle for you, and after a failed tool offset calibration, cleaning by hand is followed by a fresh purge. An upstream report against the beta asks for the calibration retry to skip the purge and only reheat and wipe, since purging again feeds the problem back in; it is open and unanswered, as is the feature request. This is a reading of the code at the v6.9.1 tag, not something an owner has confirmed by watching both failures on one machine. Neither the 7.0.0 nor the 8.0.0 notes mention either retry. The only 7.0.0 item on the wipe itself, improved nozzle wiper cleaning, is tagged as carried over from 6.10.1 (XL and XL+ firmware) and does not say what changed, and Prusa had not published the source of either release when this was written. Whether a retry still purges on 7.0.0 or 8.0.0 is therefore open.

If none of that helps

To find out whether ooze is involved at all, one owner had the printer probe with an empty tool, so that nothing could ooze; probing failed just the same, which ruled ooze out for them (thread). The cause turned out to be an assembly mistake: they had mixed up the bed spacers and inadvertently refitted the old one; once the correct spacer was in, probing worked. Single report, but the empty-tool test did its job: it ruled ooze out, and the fault was mechanical.

If probing fails with the nozzle plainly nowhere near the sheet — a gap you can see rather than one you would measure — that is a different fault entirely and ooze is not your problem. See loadcell noise. If tool offset calibration fails regardless of cleanliness and filament state, see offset sensor board failure.

Verification

reported — the symptom is reported independently by different owners with different materials.

PETG oozing and impeding bed probing is the primary thread: the original poster reports PETG oozing enough to spoil bed probing, and a second owner independently reports the same class of failure with PLA across every tool during calibration. The thread is marked answered, and its accepted answer is the sensor-window cleaning, confirmed first-hand by the person who had the problem. That is the strongest evidence on this page.

Single-source and unverified: the tool-1 temperature derivation, the declare-a-cool-filament workaround, the G-code override, the slicer configuration fix, and the hard-coded calibration temperature all come from the common problems summary, a condensation of a now-offline community knowledge base. None of it is separately confirmed in the forum corpus, and no numbers from it are reproduced here. The last of them has now been partly checked, and the check narrows it. A GitHub bug report states that the calibration temperature changed in 6.9.1 and asks for it to become adjustable (#5567). The firmware source supports a capped calibration temperature, not one that cannot be changed from G-code. The tool offset calibration at the v6.9.1 tag holds its Z-probe temperature at or below a ceiling of its own and its XY-probe temperature fixed, and the G427 handler reads only its jitter and repeat arguments, R and P, so nothing raises either one. Below the ceiling, though, the Z probe follows the loaded filament's preheat value, and the M865 handler sets that value, and the purge temperature, on any user-defined or ad hoc filament. The source comparison on the annotated profile G-code page likewise finds that temperature capped in firmware. None of the three files differs between the v6.9.1 and v6.9.2 tags, and the source of later releases is not public.

The retry behavior is read from the firmware source at the v6.9.1 tag — the bed leveling command and the tool offset calibration — and the 6.9.0 and 6.9.1 beta tags take the same retry paths. The beta changed how they run, not which steps they take: the per-tool preparation cools further, the XY scan runs cooler, and the touch on the sensor board gets more attempts before it counts as failed (see error codes). It is recorded because it accounts for every owner report in that section without contradicting any of them, but it shows what the code does, not what an owner has watched happen. Neither source file (the bed leveling command or the tool offset calibration) differs between the v6.9.1 and v6.9.2 tags, so the reading holds for 6.9.2 as well. Prusa had published no 7.0.0 or 8.0.0 tag on GitHub when this was written, so the reading has not been checked against either release, and neither set of notes names a change to either retry. Firmware 7.0.1, published on 19 October 2026 between the two, lists a single fix, for a hang at startup, and touches nothing on this page.

Where the sources disagree: drying was offered confidently as the likely cause for PETG, but the case that was actually resolved was resolved by cleaning, not drying. Do not assume moisture just because the filament is PETG — when the question was put to the original poster directly, they replied that they had been printing straight from a filament dryer, which rules moisture out for that case entirely.