Tool offset calibration fails — contactless offset sensor

Summary

Tool Offset Calibration failing repeatedly, with an error message that tells you nothing useful, is most often a faulty contactless offset sensor board rather than anything you have assembled wrongly. Clean the sensor first, because a fleck of filament on it produces exactly the same failure. If cleaning does not fix it, the resolution reported by multiple owners is a replacement sensor board — and belt tension, which support may suggest, has not fixed a single reported case.

Before you suspect the board: are you on 6.9.0?

A bug report against the firmware, now closed, describes tool offset calibration failing repeatedly after upgrading to 6.9.0, on machines where it had been working. It is no longer a couple of accounts: the report drew a steady stream of owners across both four- and eight-tool machines, including new Gen 2 builds that passed every calibration during assembly. It affects multiple tools rather than one, and the calibration wizard often succeeds while the check at print start keeps failing.

That matters here because it presents almost identically to the hardware fault this page is about, and the fix is completely different. If your calibration was fine before an update and started failing after one, you are more likely looking at this than at a failed sensor board — and replacing hardware will not help.

The strongest evidence that it is the firmware: several owners report that going back to 6.6.3 restores reliable calibration, and that returning to 6.9.0 brings the failure back.

But downgrading is not open to every machine. Support for the newer 1.5 GT belts arrived in 6.9.0, so a printer fitted with them has no earlier firmware that knows their geometry. One owner in the thread could revert only because they had refitted the original belts first. If yours are the new ones, reverting is not the workaround — it trades a calibration failure for a motion system the firmware does not model.

Part of the cause is now confirmed by the vendor's own fix. The beta release notes name two changes aimed at exactly this failure: tool offset calibration runs at a lower temperature, and the communication between the offset sensor and the main board was reconfigured to stop dropouts. The first is the ooze explanation owners had converged on — the nozzle oozes while it is heated for calibration and the deposit spoils the measurement, which is why the on-screen message asks you to check the nozzle is clean. The second is something the thread had not identified. The ooze half is the same mechanism as oozing during probing, with the difference noted there: the calibration temperature is fixed in firmware, so that page's slicer-side workarounds could never reach it. It needed a firmware change.

One configuration trap worth clearing first. 6.9.0 added support for the newer 1.5 GT belts. If your machine does not have them, that option must be off — it changes the geometry enough to matter. Several owners checked and found their settings already correct, so it is not the whole story, but it is free to rule out.

There is a vendor fix. After investigating with input from owners on the report and tracking the fault internally, the vendor published 6.9.1-beta for the Core One INDX on 10 September 2026. Alongside the temperature and communication changes it lets calibration retry its Z probing up to 10 times instead of 3, and lists a fix for tool offset recovery. The calibration temperatures themselves are in the release notes and are not repeated here. Several owners on the report say calibration now passes first time where it had been failing every time, and the owner who opened it has since said the beta fixes it for them and that it could be closed. A Prusa developer closed it on 23 September 2026, on the grounds that most owners who had the original failure appeared to be rid of it. The closing comment names no release and does not answer the owner below who reported occasional failures continuing on the beta; anyone with a similar problem, or any other tool offset problem, is asked to file a new issue and to cite this one where it is related. The fix does not touch the temperature used for bed probing, which comes from the slicer profile rather than firmware — see oozing during probing.

It is now in a stable release. The vendor published 6.9.1 as stable on 25 September 2026. Its release notes list a gantry squareness wizard and a homing fix, and say nothing about tool offset calibration. The beta's changes are in it all the same: in the firmware repository the stable tag is the beta tag plus 15 further commits, and none of them touches the tool offset calibration or offset sensor code. That comes from reading the repository, not from the notes, and nothing in the stable is described as a further fix for this failure. 6.9.2, released on 7 October 2026, carries the same code. On the INDX it changes nothing but the PVA and BVOH filament presets, which the 6.9.1 notes had announced and which that release left out. 7.0.0, published on Prusa's downloads page on 15 October 2026, says nothing in its notes about tool offset calibration or the offset sensor. Prusa has not yet published its source, so unlike 6.9.1 and 6.9.2 there is no way to check whether it carries the same code. The notes do list improved nozzle wiper cleaning, marked as first shipped in 6.10.1; the one report since that ties what cleaning leaves on INDX nozzles to calibration failures groups 7.0.0 with 6.9.2, both much worse than 6.9.0, without comparing the two or mentioning the cleaning change, see below. Neither of the two releases since says anything more about tool offset calibration. 7.0.1, published on 19 October 2026, lists a single fix, for the startup hang described further down this page. The notes for 8.0.0, published on 22 October 2026, mention neither tool offset calibration nor the offset sensor; their one item on nozzle cleaning slows flexible filaments down less while they are cleaned. Neither source is published, and no owner has yet reported on calibration under 8.0.0.

The beta was not clean for everyone, and the stable notes mention none of what follows. One owner finds calibration passing reliably but nozzles coming out noticeably dirtier. Another reports failures continuing, less often than before, and a third found the beta dragging strings of filament onto the nozzle and failing Z probing, and did better going back — though they suspect their own wiper setup. None of these is confirmed beyond its reporter. A thermal runaway reported on the beta was withdrawn by its reporter, who said the same files reproduced it on the earlier release and suspected their model rather than the beta.

The first report on the stable is not clean either. One owner with an eight-tool machine reports on firmware issue 5500 that on 6.9.1 the calibration at print start still fails often on prints that use several tools, often enough that starting one means a long spell of cleaning nozzles by hand. They put it down to material the purge leaves on the nozzles, which they say is too much on both 6.9.0 and 6.9.1 and is often still on the nozzle after wiping. That is material on the tip, the cause the on-screen message names; it says nothing about the sensor dropouts or a failing board. They also report the failure screen presenting the wrong tool to clean, see error codes. Two more owners have since added to the issue that they see the same, one on a four-tool Gen 2 machine and one who finds ASA, which sticks more, close to unprintable, neither with more detail. The issue is open with no reply from the vendor.

One owner says the lower temperature makes things worse with PETG. provisional, a single report. On a Gen 2 machine, they report in firmware issue 5567 that PETG still clings to the nozzle once the cleaning has finished and probing is about to start, and that it gives a Z offset that is too high and failed probing. On 6.9.0 that happened now and then; on 6.9.2 and 7.0.0 they find it much more frequent, and going back to 6.9.0 helps a good deal without curing it. They put it down to the lower calibration temperature that 6.9.1 introduced: at that temperature PETG left on the tip has set hard, so it upsets the measurement more. They add that the stock start G-code runs this calibration ahead of the print's own nozzle cleaning step, and suggest cleaning first. The calibration still runs its own per-tool clean before measuring, so the request is for an extra clean ahead of it. If they are right, then for a sticky material the lower temperature, the half of the vendor's fix aimed at ooze, works against its own purpose. Nobody has tested that, and the vendor has not replied. It is material on the tip again, not the board.

The first reports on 7.0.0 do not point at the board. Each is a single report. One owner in the tool offset thread, who had no failures on the 6.9.1 beta or the stable, saw calibration fail on their first print after updating and pass on the first retry; they were not at the printer when it failed. Another, with an eight-tool Gen 2 machine, reports in firmware issue 5548 that on 7.0.0 multi-tool prints often stop at the start with 36130. Their log places it at the touch on the sensor board, before any sensor sweep, which is a loadcell measurement, and they suspect loadcell noise that they measured rising when the extruder motor is energized. They later report that switching the extruder driver off before the probe made the failures rare on their printer, a workaround rather than a fix. Their later setup switches the bed's status light off as well, which they describe on firmware issue 5518 as very reliable so far; that result does not separate the motor from the light. A second owner on firmware issue 5548, with an eight-tool machine on which no firmware so far has made the calibration reliable, switched only the extruder driver off and had the probing pass first time after several failures; that is one attempt, and their firmware is not given. See error codes and loadcell noise.

For owners with the newer belts the fix also removes the dilemma above: 6.9.1 is INDX firmware that keeps 1.5 GT support, so moving forward replaces downgrading as the way out, and with the stable release out that no longer means installing a beta. The firmware links an official help article for this error code, which owners say did not resolve it.

A lead: some offset sensor board failures may be a clock setting

provisional — one report, and its author says it is not yet proven.

An owner who hit the sensor's first-sample failure on both 6.6.3 and 6.9.0 replaced nearly everything in the signal path without clearing it: two offset sensor boards, several cables including one run outside the printer, two main boards, the motors, the carriage and the power supply. What cleared it involved no hardware at all. A firmware build that doubled the reference clock divider on the offset sensor's LDC1612 chip — taking its reference frequency from 40 MHz to 20 MHz — got all eight tools through calibration at the first try.

The reasoning can be checked against the chip's datasheet, which caps the reference frequency at 35 MHz in the single-channel mode the INDX uses — below what stock firmware set through 6.9.0. If that is the cause, units with a little less margin would fail intermittently while most carry on working, which would also account for a replacement board curing the same error for some owners without the fault ever being widespread.

Treat it as a lead rather than a fix: one machine, a custom build, a result the reporter was still repeating, and a write-up they disclosed was drafted with an AI assistant. See firmware issue 5473.

The vendor made the same clock change. The 6.9.1-beta source, and so the stable 6.9.1, halves the sensor's reference clock. The commit gives the datasheet's single-channel limit as its reason and is dated before issue 5473 was filed; 6.6.3 and 6.9.0 both ran the chip at 40 MHz. The release notes do not mention it, so whether it is what they call the communication fix is not stated. That settles the premise, not the cure: no owner has yet reported whether stock 6.9.1 clears the first-sample failure on a machine that had it. Nor would such a report single out the clock. The reporter's build changed only the reference divider, but the vendor's commit also divides the sensor's input clock, drives the coil at a fixed, lower current with automatic amplitude correction off, and changes which amplitude and stalled-oscillation errors get reported. If stock 6.9.1 clears the failure, any of those could be why. If your board fails this way on 6.9.0 or earlier, updating costs nothing and is worth doing before you replace it.

Error codes that lead here

Code What the printer shows
36130 Tool offset failed
36136 Calibrate dock from menu
36194 The tool offset sensor sent no usable data

36130 is this page. It is also the code the firmware links its own help article for, which the owner reporting the 6.9.0 regression says did not resolve their case.

36194 exists only in firmware built from hyiger/Prusa-Firmware-Buddy, which reports this fault as its own code when no sweep got usable data from the sensor. On stock firmware the same fault is 36130; error codes shows how to recognize it in the serial log.

Detail

Two different sensors are involved in setting up an INDX, and knowing which one has failed saves a great deal of wasted effort. The loadcell handles Z contact against the bed. A separate contactless inductive sensor on its own small PCB handles tool offsets. In this failure mode the loadcell Z-probe passes fine; it is the contactless sensor that returns no readings at all, so calibration has nothing to work with.

The firmware log carries a distinctive fingerprint — an error naming the contactless offset routine together with a failure to obtain a first sensor sample. That log line is the single most useful thing you can capture, because the on-screen message is generic and the on-screen suggestion to clean the nozzle is misleading.

What makes this fault confusing:

  • The tool number where it fails is not diagnostic. Owners report failing on the first tool, and others report getting several tools in before failing, with the stopping point moving between attempts and no changes in between. Different stopping points do not mean different problems.
  • Swapping tools around does not help, and neither does re-seating the tools. Several owners worked through permutations before concluding the sensor was at fault.
  • Belt tension is a red herring here. It is a reasonable first guess and support has suggested it, but owners who squared and re-tensioned the gantry thoroughly report no change. Do not spend a night on it before capturing a log.
  • Cable continuity testing good does not clear the sensor. One owner checked the cable, found it electrically fine, and the board was still the fault. Cable replacements on their own have not fixed reported cases.
  • Not every hardware case ends at the sensor board. provisional, one report. One owner on 6.6.0 and 6.6.1 had 36130 whenever a print started, although the calibration itself could complete, and their loadcell test showed unstable readings, though a press on the nozzle still registered once the warning was dismissed. Belt tension and repeated calibration did not help. The fault turned out to be in the part they call the tool holder, which they took up with the manufacturer under warranty, and everything has worked since. The post does not say which part that is. The same split, calibration completing while the print start fails, is listed above as a sign of the 6.9.0 regression; here it came before that release and was hardware.
  • Passing from the menu and failing at print start also fits loadcell noise. provisional, owners in one forum thread and on one issue, most of whom changed several things at once. Owners in the tool offset thread cleared failures at print start by rerouting and twisting supply and heater wires and fitting ferrite chokes. One of them, on stock 6.9.2, still had the odd failure after the rewiring. They read firmware issue 5526, whose opener blames the bed's status light on the strength of testing done on firmware they had modified, switched the light off from the menu, and had no more failures. They then fitted ferrite beads to the bed and chamber light cables as well, and their latest summary, on firmware issue 5518, credits their complete fix to the rewiring, those beads and a lower probing temperature in the start G-code. Switching the light off is not on that list, though they think the bed light's cable was the likeliest source, so their result does not show that switching it off is needed. Another owner in the thread switched the lights off and fitted ferrite beads at the same time, and their failures stopped too. A further owner, on firmware issue 5526, found that ferrite beads did not help and that switching the light off has so far seemed to help every time; they do not give their firmware. One owner describes the light as lit during a print and not during a calibration from the menu. That is the other sensor, see loadcell noise.
  • A startup that hangs at the offset sensor on 7.0.0 is a separate problem, fixed in 7.0.1. reported, two sources. Several owners on 7.0.0 report the printer stopping during startup at the offset sensor stage after they reset it with a print starting or a tool on the head (thread), and the owner who opened firmware issue 5544 describes the same hang on every boot after resetting the printer during a crash in Z homing. Every report that says how it began follows a reset, and nothing in either source points at the sensor board. Prusa's notes for 7.0.1, published on 19 October 2026, list one change: a fix for Core One INDX printers hanging at startup on the screen that reports the tool offset sensor as ready. The owner who opened the thread reports bringing the hang about again and finding that 7.0.1 fixes it. No owner has said whether, or how, they put 7.0.1 onto a printer that was already stuck. The flashes onto stuck printers that owners describe were downgrades: two owners got their printers starting again by flashing 6.9.2, one of them with a forced flash, and a third, whose first attempt to downgrade had stopped at the same boot screen, got 6.9.1 installed by pressing reset and then holding the knob down until the installation began. Two others found that going back did not help, and a factory reset helped nobody who tried it. Three owners, two in the thread and the one on the issue, recovered without new firmware by booting once with the INDX cable disconnected, at the main INDX connector or at the xBuddy board. In the thread the steps are: with the printer off, unplug it, switch on once, switch off, reconnect it and switch on again. The issue's report does not say whether the printer was off when they unplugged it; switch it off before you unplug either connector.

What to do, in order

  1. Clean the sensor itself, not just the nozzle. A small piece of filament debris sitting on the sensor face causes an identical failure, and this is the one cause you can fix yourself in a minute.
  2. Capture a firmware log over the USB-C serial connection and keep it. This is the evidence that gets a support case resolved quickly — at least one owner reports the vendor confirming the board as faulty specifically on the strength of submitted logs. TODO(verify): the serial baud rate to configure. It is stated in the summary thread, but a reader will type it into a terminal, so it needs checking first.
  3. Check the LED on the sensor PCB. If it keeps blinking rapidly once a calibration has already failed, that points at the board itself — the rapid pattern is only meant to appear while the sensor's microcontroller is being flashed. Seeing it outside of a firmware update is a strong signal.
  4. Open a support case. The reported route is diagnosis with Prusa first, then a Bondtech ticket for the replacement board, carrying Prusa's findings with it. A ticket that already says what Prusa identified moves faster than one starting from symptoms. Open it early even if you are not ready to act, so the date is on record — see who to contact.

The sensor works on eddy currents, which is worth knowing for two reasons: it is why a non-conductive nozzle tip is a design constraint for future nozzle variants, and it is why surface contamination on the sensor matters as much as it does.

A board-to-board comparison reported in the summary found that a failing unit and a working unit were the same hardware revision from the same production batch, so this looks like unit-level variance rather than a bad batch you could identify from a serial number.

One suggestion in the threads is not a repair

Reflow-oven reworking of the sensor board was floated by an owner as something they might try. There is no report of anyone doing it successfully, and it would almost certainly end any warranty claim on the part. Get the board replaced.

Verification

reported — two independent threads, two different owners, both ending at board replacement.

Offset sensor failure documents calibration failing on the first tool and establishes the support route that owners converged on. Tool offset calibration failing is a separate owner with a different-looking presentation — failing partway through the tool sequence, intermittently — who worked through belt tension and tool swaps without improvement, verified cable continuity as good, and reports the vendor confirming the PCB as the fault after reviewing submitted logs. That two dissimilar symptom patterns resolve to the same component is the most useful thing on this page.

The log fingerprint, the LED diagnostic, the eddy-current mechanism, and the same-batch comparison come from the common problems summary, a condensation of a now-offline community knowledge base. Those specifics are single-source and have not been separately confirmed in the forum corpus.

Where the sources disagree: support's own first suggestions varied between cable and board, and in one case belt tension was raised. Owner experience points consistently at the board, with one exception: a single owner whose fault was in what they call the tool holder (thread), marked provisional where it appears.

Added since first publication. The 6.9.0 calibration regression comes from the firmware issue tracker, which is a stronger class of source than the forum for firmware behavior — it is first-party, versioned and reproducible. What began as two accounts has become a long thread of independent reporters on both machine sizes, several of whom resolved it by downgrading. That reciprocal test — fails on 6.9.0, works on 6.6.3, fails again on 6.9.0 — is what makes the regression itself well supported.

The cause is now partly established. Where this page previously had only owners converging on ooze, the vendor's beta release notes name a lower calibration temperature and a fix for offset sensor communication dropouts, and the developer on the report said both mattered. That is the vendor naming contributing causes, not a published root-cause analysis. The fix has since left beta. The report was closed on 23 September 2026 on the strength of owner feedback on the beta, and the stable 6.9.1, and 6.9.2 after it, carry the same code, which the release tags show and the notes do not say. That makes it the vendor's released fix, not a verified cure: one owner on the report still saw occasional failures on the beta, and the first owner to report on the stable, in a separate issue, still sees calibration fail often on prints that use several tools, which they put down to purge material left on the nozzles. The notes for 7.0.0, 7.0.1 and 8.0.0 say nothing about it, and none of their sources is published yet. The first two reports on 7.0.0, one in the forum and one on the issue tracker, each describe a failure at print start, and neither is put down to the sensor board. A third, on another issue, blames the lower calibration temperature for PETG left on the nozzle; that is a single report. There are none yet on 8.0.0. The startup hang on 7.0.0 rests on the forum thread and the issue linked where it appears; that 7.0.1 fixes it is Prusa's notes and one owner's test.

The LDC1612 reference-frequency lead is a separate single report from a different owner, and is marked provisional where it appears. The vendor's own commit confirms that the clock exceeded the chip's limit and changes it, alongside several other sensor settings, but says nothing about whether that caused the failures that owner saw.

  • Bed not aligned in Z — the same error code on a clean machine with nothing loaded; a free calibration to run before suspecting the board
  • Probing fails or nozzle never touches the bed — the other sensor, frequently confused with this one
  • Assembly notes — if this is failing on a freshly built machine that has never calibrated successfully, check the build first: this is one of the two selftest failures that recur on new conversions
  • Dock calibration rejects some or all docks — where a mismatched 1.5GT belt setting is the first thing to check
  • Who to contact — getting the replacement part: diagnosis from Prusa, hardware from Bondtech, and open the case early enough that the date falls inside your warranty window.