Phantom tools, "tool not detected" and park failures¶
Summary¶
The INDX decides whether a tool is present by pinging an induction coil in the head and measuring how the ringing dies away — the firmware calls this the ringdown decay value. There is a band in the middle of the scale where the reading is ambiguous, and in that band the firmware keeps whatever it last believed. That single design detail explains most of the confusing behavior in this family: why a wrong tool state persists, why it survives a retry, and why two machines with opposite symptoms can have the same underlying cause.
Error codes that lead here¶
| Code | What the printer shows |
|---|---|
36125 |
Tool pickup failed |
36127 |
Tool park failed |
36128 |
Retry tool park |
36124 |
Tool lost |
36123 |
Occupied dock |
36202 |
Hotend preheat error |
36135 |
Toolchanger error |
Detection faults surface as one of these. 36125 and 36127 are the two halves
of the problem this page describes — a tool that will not read as picked up, and
one that will not read as parked. 36128 is the retry that usually succeeds.
Detail¶
Readings come out at one of three conclusions: clearly no tool, clearly a tool, or ambiguous. In the ambiguous middle the firmware holds the last known state rather than guessing. That is a sensible design, but it means a machine whose readings sit in or near that middle band gets sticky wrong answers instead of intermittent ones.
Reading the value on your own machine¶
The live figure is on the printer at Info → Sensor Info → Ringdown Decay.
Two owners have posted readings from healthy machines, and they agree closely:
| Head empty | Tool docked | |
|---|---|---|
| Machine A | 29 | 101 |
| Machine B | 27 | 103–104 |
Two machines is not a survey, so treat this as "roughly what healthy looks like" rather than a pass mark. But they were taken independently, from the menu above, and they land within a couple of points of each other at both ends — which is more than the forum offered before. A reading close to these with the head empty means detection is probably not your problem. One sitting well above them is worth investigating.
TODO(verify): whether the reading drifts once the head and coil are warm. An owner raised this after noticing their machine misbehaved despite healthy cold readings, and suggested someone take a reading part-way through a long job, or immediately after one, to compare against the cold figure. Nobody has reported doing so. The community summary separately records the idle floor rising with ambient temperature, so the question is a reasonable one.
Prusa's own release notes for firmware 6.9.0 name the "nozzle presence" decay
threshold and give both its old and new value: it moved from 0.095 to 0.085. Prusa
frames this as easing the upper bound in the interest of more reliable detection. That
is a first-party figure, so it is published here. Note the scale: the community
discussed these readings multiplied by a thousand, so a forum post describing a
threshold of "95" and the changelog's 0.095 are the same number.
TODO(verify): the lower threshold. A figure circulates on the forum but the owner quoting it hedged it as a belief rather than a reading, and Prusa's release notes name only the upper one. Also outstanding: how idle readings differ between controller board revisions, which remains a community claim with no published figures behind it.
Two opposite symptoms, one mechanism¶
Reads a tool that is not there (phantom tool). The head's idle reading sits high enough to be taken as "tool present" when the head is empty, so the machine believes it is holding a tool it is not.
Note that a park failure is not reliably a symptom of this. It looks like one — the machine insists a tool is present after parking — but there is a separate, better-documented cause with a different fix, covered further down. If your tool physically parks correctly and a retry clears the error, read that section before concluding your head is marginal.
Reads no tool when one is fitted. The mirror image: a real tool picked up from the dock reads just below the "tool present" conclusion, so the firmware reports the tool was not detected after pickup. A distinguishing feature is that it tends to happen at the same dock position every time.
Three things influence where a given head sits:
- Controller board revision. Idle readings on an empty head differ systematically between xBuddy board revisions, while readings with a tool docked are much more consistent across revisions. Owners on the earliest revision are the most affected population.
- Ambient temperature. The idle floor drifts upward as the room gets warmer, so a machine that is fine in the morning can misbehave in the afternoon.
- Time in service. Several machines have settled downward over days of printing, moving from marginal to comfortably healthy without intervention. If you are close to the edge, running the machine may help rather than hurt.
A genuinely faulty head reads high at idle regardless of which board it is plugged into and regardless of the cable. Where that has been tracked, board swaps and replacement main cables changed nothing, and the resolution was a replacement toolhead from the vendor. On at least one such unit a wire strand was found coming away from the coil itself, and owners have raised coil wear and damaged coil wiring as a wider quality question.
The preheat error is probably not a separate problem¶
There is a preheat error that fires on first-tool pickup during Tool Offset Calibration on affected machines. The evidence points to it being secondary to detection: the firmware will not drive the heater of a tool it does not trust is present. On one machine a toolhead replacement cleared both the detection fault and the preheat errors together. Treat them as one complex, and chase the detection problem rather than the heater.
Modified firmware thresholds — read before you go looking
Some owners have compiled custom firmware with the detection thresholds altered so their machines print again. Understand what that involves before you consider it. On this hardware it requires an irreversible physical modification to the controller board. It is unsupported by both companies. And it works by making the firmware more willing to trust a marginal reading — which is the correct move if your head is healthy and the firmware is too strict, and the wrong move if your head is genuinely failing, because it masks a hardware fault you would otherwise have replaced under warranty.
This page does not supply build instructions. Firmware 6.9.0 has since made this change officially, which removes most of the reason anyone was doing it by hand — update before you consider patching anything. Establish first, with the vendor, whether your head is faulty.
Firmware 6.9.0 relaxed the detection threshold — what that means for you
Prusa's release notes for 6.9.0 record two related changes: they eased the upper bound on nozzle-presence detection, citing more reliable detection as the goal, and moved the decay threshold from 0.095 to 0.085.
If your fault was a tool reading as missing after pickup, this is the change you were waiting for. Readings that previously fell just under the old bar clear the new one, so update before pursuing a replacement toolhead.
If your fault is park detection, see the section below. An earlier version of this page suggested the threshold change might be causing it. Better evidence has since arrived and points elsewhere, so that suggestion has been withdrawn.
Treat any pre-6.9.0 threshold figure you find on the forum as describing the old behavior.
"Tool is still detected after parking" is a timing problem, not a threshold one¶
This deserves separating from the rest of the page, because the mechanism is different and so is the fix.
A bug report against the firmware, filed with logs, describes parking failing to confirm the nozzle as absent on 6.6.3. The routine that verifies nozzle state times out, logs that the nozzle is still detected after the park, retries, times out again, and the toolchange fails. The tool has physically parked correctly throughout — it releases and stays in the dock. Roughly twenty seconds later the firmware works it out for itself and corrects its own record to "no tool", so the reading does settle. It simply settles long after the verification window has closed.
Two details make this convincing. The reporter downgraded the same printer to 6.6.2 and the problem disappeared completely, with nothing else changed. And picking a tool up from an empty head works fine — it is specifically the park that fails.
Why this matters for the threshold story above: the park failure was already present in 6.6.3, which is before 6.9.0 relaxed the detection threshold. So the threshold change cannot be its cause, and an owner reporting park messages on 6.9.0 is most likely seeing this same longstanding bug rather than a side effect of the relaxation. If your park fails but the tool is physically docked and a retry clears it, you are probably looking at the settling-time problem, not a marginal head.
A second line of evidence points the same way. One of the owners who posted the healthy readings above — comfortably clear of any threshold at both ends — is the same owner whose machine had been reporting failed unloads. A head reading that healthy cannot be marginal, so whatever caused their park messages was not a borderline detection value. That is consistent with a settling-time problem and hard to reconcile with a threshold one.
TODO(verify): the verification timeout the firmware allows, and how long the reading actually takes to settle. Both are quoted in the linked issue, which was closed for inactivity without a resolution.
Firmware 6.9.1 does not change this. 6.9.1 went stable on 25 September 2026, after a beta on 10 September. Neither set of release notes mentions nozzle-presence detection or the park check, and the public source bears that out: between the 6.9.0 and 6.9.1 release tags the work is in tool offset calibration, parking and calibration moves, homing, a Wi-Fi fix, a new gantry squareness wizard and filament presets, and the code that reads the coil and sorts the decay into present, absent or unknown is untouched. The 6.9.0 threshold still stands. Nobody added to the bug report after July, and GitHub's stale-issue bot closed it on 5 October 2026 for inactivity, as not planned, a week after warning that it would. That closure is not a fix: no developer replied and no change is linked to it. No owner has yet reported the still-detected-after-park failure on 6.9.1, so this is a reading of the source rather than a result from a machine. Firmware 6.9.2, released on 7 October 2026, does not change it either: between the 6.9.1 and 6.9.2 tags the only change that reaches an INDX is the PVA and BVOH filament presets. Firmware 7.0.0, dated 15 October 2026 on Prusa's downloads page, lists nothing on nozzle-presence detection or the park check, and neither do the notes for 7.0.1 (19 October 2026, a single fix for a freeze at startup on the offset sensor screen) or 8.0.0 (22 October 2026). Prusa had not published the source for either when this was written, so that is the notes' silence, not a reading of the code.
Verification¶
reported — the fault family is described independently by multiple owners across
several threads and more than one firmware generation.
First-hand and current: 6.9.0 firmware, tool docking is an owner reporting park-detection errors that began with 6.9.0, on a machine where parking itself always succeeds — a clean example of the detection layer disagreeing with physical reality, and independent evidence that this family is live on current firmware. Will the Prusa INDXs wave1 ship with fixed induction coils? shows owners treating coil wear as a known concern ahead of the retail wave, though that thread is speculation about quality control rather than diagnosis, and one participant in it confuses the coil issue with the separate nozzle issue.
A correction. An earlier version of this page suggested 6.9.0's relaxed threshold might explain the "tool is still detected after parking" reports, flagged at the time as an inference rather than a claim any source made. A firmware bug report has since shown the park failure occurring on 6.6.3 and disappearing on a downgrade to 6.6.2 — before the threshold moved at all. The suggestion has been withdrawn and the park behavior now has its own section, where the evidence points at a settling-time problem instead. The issue was closed for inactivity without a resolution, so that account may yet change too.
First-party. The 6.9.0 threshold change — both the relaxation and the specific decay values — comes from Prusa's own release notes, which is the strongest class of source on this site: dated, unambiguous, and published by the people who wrote the firmware. It also retrospectively supports the community's threshold model, since the value Prusa names matches the figure owners had derived, differing only by the factor of a thousand in how it was written down.
Single-source, and the main caveat on this page: the three-band threshold model, the board-revision differences, the temperature drift, the break-in effect, and the preheat-error relationship all come from the common problems summary, which condenses a community knowledge base that is now offline. That condensation is detailed and internally consistent, but it has not been independently reproduced in the forum corpus, and it predates 6.9.0. The explanatory mechanism should be read as well-sourced-but-unverified rather than established.
The vendor's position, as reported there, was that the investigation remained open between "hardware fault" and "firmware too strict". Both turned out to be real for different machines, which is why this page leads with the mechanism instead of a fix.
Related¶
- Probing fails or nozzle never touches the bed — a different sensor and a different fault, but both are "the printer believes something untrue about its own state"
- Tool offset calibration failures — where the preheat error tends to surface
- Toolhead collides with finished parts — the other thing that can go wrong around a park and a tool change, and the more destructive one. Unrelated mechanism: a motion-clearance fault, not a detection one.
- Blobs dragged into the print — the other area 6.9.0 reworked. Owners report that change as a clear improvement, which is worth weighing against the park-detection regression described above.
- Tool unlocks or ejects from the head — the tool physically coming loose rather than being misdetected; one owner found a defective gear in the lock
- Who to contact — for a toolhead replacement