One cause is confirmed twice; the others rest on one machine or one thread

A belt-type setting that does not match the fitted belts has stopped dock calibration on a large, unchanging Y error on two machines, reported in two unrelated places: every dock in one report, and in the other a Y reading that would not move. Correcting it, directly or through the printer variant, fixed both. That part is reported. A dock row that fails only at one end, blamed on gantry skew, comes from one unresolved machine, and a squareness wizard held back by the docks themselves from one other. The slack-belt fix for a uniform shift rests on one owner, and the belt and homing advice for a failing first dock comes from several owners, all in a single forum thread. Those parts are provisional and are marked where they appear.

Summary

Dock calibration measures where each dock actually is, then accepts the measurement only if it falls inside a narrow window around a position compiled into the firmware. It records each dock's measured position, but only if it lies within that window, so it cannot adapt to a machine whose docks sit outside it. So when docks are rejected, which docks fail, and in which direction, is the clue:

  • Docks off in Y by the same amount — or just the first dock, if calibration never gets further. X was within tolerance in both reports (on every dock in #5444). Check that the printer's 1.5GT Belts setting matches the belts physically fitted. Two owners fixed it by matching the belt setting to the hardware, one directly and one via the printer variant. A third, with a smaller uniform shift the other way, fixed it by tightening slack belts instead (one owner, provisional).
  • The error grows steadily along the row, so only docks at one end fail. The row is straight but rotated against the X axis. A Prusa developer suspects an out-of-square gantry; the one owner with this pattern has not resolved it. provisional.
  • The first dock fails and nothing else looks wrong. Owners in one thread point at slack belts, gantry squareness and homing calibration. Two later owners in the same thread got dock calibration to pass by tightening the belts a step at a time between attempts, though neither described a first-dock-only failure: one found every dock off, after a stuck tool and repeated homing failures (compare the slack-belt case in the first bullet). provisional.

Error codes that lead here

Code What the printer shows
36136 Calibrate dock from menu

36136 sends you to run dock calibration from the Calibrations menu. If that calibration then rejects a dock, this is the page.

Detail

What the calibration checks against

The firmware holds an expected position for every dock: its own X for each dock, and on the Core One a single Y shared by all of them. The Core One L has its own figures, and the source marks its Y as still needing validation on more printers.

During dock calibration, a measurement outside a fixed window around its expected position fails that dock. The failure screen shows the measured and expected values and offers a retry. Without a retry, the dock is marked uncalibrated, its tool is disabled, and the wizard ends there, leaving any later docks unmeasured. A measurement inside the window is stored and used from then on. Separately, the firmware stops with a toolchanger error rather than use any stored dock position that falls outside the window.

TODO(verify): the expected dock positions and the width of the acceptance window. The expected positions are compile-time constants in indx_dock_position_defaults.hpp; the window, a per-axis offset plus a slack for display rounding, is in toolchanger_utils.h. Both were read at the 6.9.1 tag and are withheld until checked against a machine.

Two consequences follow. A machine whose docks are all shifted by the same amount cannot pass, however accurately it measures them. And because one Y serves every dock, a row that is perfectly straight but slightly rotated fails only at the end furthest from the expected line.

The wizard's reading is consistent: in the first report below, a manual check agreed with it closely. In that case, though, both were made with the same wrong belt scaling, so the agreement rules out a measuring fault, not a configuration one.

The reporter of the first case says the machine could neither run other calibrations nor print while the docks stood rejected. That is one account; the firmware disabling the tool of an uncalibrated dock is consistent with it.

Firmware 8.0.0 gives this calibration one line in its release notes, dated 22 October 2026: the head now approaches the dock more gently. That is all Prusa says. The line does not say whether speed, force or path changed, and it mentions neither the expected positions nor the window, so this page has no reason to think the checks above changed but cannot confirm it until Prusa publishes the 8.0.0 source. No owner has yet said whether the change alters which docks pass.

Docks rejected by the same amount in Y: the belt setting

On an original Core One converted with the INDX kit, every dock measured short in Y by the same distance, while X was within tolerance on every dock (#5444). A factory reset and a fresh flash changed nothing. A Prusa developer pointed to the belt-type setting as the likely cause, and so it proved: the machine had the older 2GT belts while the firmware was set for 1.5GT. Changing the setting to match and rerunning dock calibration passed every dock.

The owner explains that the reset did not help because the setup wizard asks again which printer variant you have, and giving the same answer put the same belt setting back. Prusa's firmware source fits that account. Its printer setup screen lists the variant and, separately, the belt setting, and the two are tied together: of the three Core One variants (Core One, Core One+ and Core One+ Gen2), only the Gen2 one switches the 1.5GT belt setting on, along with other features of that edition, and choosing either earlier variant switches it off. By default the firmware applies the Gen2 variant on first run and after a factory reset that clears the hardware configuration, at both the 6.9.0 and 6.9.1 tags, which fits the developer's remark below that the default is 1.5GT. A machine without the Gen 2 upgrade has to be set back after any reset.

Why the error appears in Y: the belt setting changes the X/Y steps per millimeter the firmware uses, so on the wrong belts every move is scaled by a small fixed percentage. The error grows with distance from home, and the docks sit at the far end of the Y travel. Same-sized Y error on every dock is the signature. The setting changes X steps as well, but #5444 found X within tolerance on all five docks, so X error is not part of the reported signature.

Both reports had the 1.5GT setting on 2GT belts. The head then moves further than the firmware counts, and the docks read short of their expected Y, nearer to home. By the same arithmetic, the opposite mismatch would put them beyond it; this is the page's own inference, and neither report covers that case.

TODO(verify): how large that uniform shift is at the docks. A figure is worked through in

5444; it is withheld as an offset magnitude until measured here.

A second owner, in an unrelated forum thread, hit the same wall: docking failed with a Y reading that would not move whatever they tried, and the figure they quote is essentially the one in #5444 (toolhead docking calibration fails). Their printer was configured as a Gen 2 machine although none of the Gen 2 parts, which include the newer belts, had been fitted yet. Selecting a non-Gen 2 printer variant in the system settings, which per the source above also switches off the 1.5GT belt setting, let dock calibration pass, on the second run. The variant change switched off the other Gen 2 features along with the belt setting, so on its own it does not single out the belts; the Y figure matching #5444's is what points to them.

They believe flashing the firmware for the conversion switched the configuration to Gen 2 by itself. A separate owner, in another thread, saw the same right after flashing the INDX firmware: the printer had assumed the Gen 2 belts were fitted, correctly in their case, though it could not have known. Prusa's source applies the Gen2 variant on a first run, which would explain both. That flashing the INDX firmware counts as a first run is inferred from the source, not confirmed.

Which belts do you have? The Gen 2 upgrade brings the 1.5GT belts. According to the Prusa developer on #5444, the firmware defaults to 1.5GT, and a Core One+ without the Gen 2 upgrade most likely has 2GT; the original Core One in that report had 2GT as well. If in doubt, count teeth over a measured length: a 1.5GT belt has a third more teeth than a 2GT belt over the same distance.

The printer itself warns, when you change the setting, that the wrong choice causes dimensional and homing errors and that some calibrations will be reset. Prusa's source shows which: changing it resets the homing, belt-tuning, gantry-squareness and X/Y axis self-test results. So restart if the printer asks you to, then rerun the calibration sequence from the start rather than dock calibration alone. The same setting is the first thing to rule out for tool offset calibration too; see tool offset calibration fails.

Not every uniform shift is the belt setting. provisional — one owner. In the same forum thread, an owner whose docks all came out off in Y by one smaller, shared amount, and beyond the expected Y rather than short of it, fixed it by tightening belts that had been far too slack, with no change to the belt setting mentioned. Their belts rang at the right pitch even while loose. They tightened them well past that point, then alternated between squaring the gantry and retuning the belts until neither disturbed the other, and finally reran every calibration from the start, after which dock calibration passed. That is one owner's method, not Prusa's procedure: follow Prusa's belt-tension guide, and do not over-tension.

Error that grows along the row: a rotated dock line

provisional — one machine, unresolved.

On an eight-dock Core One+ (Gen 2) on 6.9.1-beta, the owner reports the belt setting correct for their Gen 2 belts, and three runs per dock repeated almost exactly (#5491). The measured Y crept steadily from the first dock to the last, on a near-perfect straight line. The last two docks fell outside the window and the one before them sat on its edge. The owner inspected the tool holders, and every dock sat on the same line, which rules out a single dock out of place.

The owner had first ruled out squareness by measuring printed squares, but had already noticed, before Prusa replied, that one side sat further out even with the gantry nominally square. A Prusa developer read it as a gantry that is not square and pointed to the squareness wizard new in 6.9.1. Run on that machine, the wizard reported skew well outside the tolerance the developer then quoted, above which homing is said to become unreliable. The owner says squaring the gantry by the guide makes gantry calibration fail, while skewing it so one side shows a gap lets that pass and breaks everything else. After weeks with support it was still unresolved on 29 September 2026.

On 8 October 2026 the developer came back with questions rather than a fix. They asked what the owner means by gantry calibration failing, said they could not see how skewing the gantry would let it pass, and asked whether the nozzles had been taken out of docks 1 and 8 before the squareness check, as the wizard instructs. The owner had not answered when this page was updated.

TODO(verify): the gantry squareness tolerance the Prusa developer quoted on #5491. The 6.9.1 wizard passes against the same figure, a constant in indx_gantry_squareness.hpp that its result screen also shows. Withheld as an assembly setting.

How the wizard measures bears on that exchange. Prusa's 6.9.1 source shows it homing first, then driving the empty head into the two outermost docks until it stalls, and taking the difference between the two stopping points in Y as the skew. It asks for docks 1 and 8 to be emptied beforehand, and if the measurement itself fails, it asks you to check that they are; a skew reading over the limit instead tells you to align the gantry by the guide. It follows that the wizard judges square against the dock row: it reads the same tilt that dock calibration rejects, and by itself it cannot tell a skewed gantry from a dock row sitting out of line with a square one. Were this machine's docks out of line, squaring the gantry by the guide would fail the wizard and skewing it to follow the docks would pass, which matches the owner's account, if the gantry calibration they mention is this wizard, something the developer has asked them to clarify. That is this page's reading of the source, not Prusa's explanation, and nobody has checked it on the machine.

The owner has asked Prusa to validate docks against a line fitted through the measured docks, rather than one fixed Y, so a uniformly rotated row could pass while a single displaced dock would still stand out. That request is open and labeled as an INDX enhancement, with no commitment from Prusa.

The squareness wizard held back by the docks

provisional — one owner, one thread.

A second report on the squareness wizard comes from another machine, and there the docks themselves were plainly involved. On an original Core One fitted with the Gen 2 and INDX upgrades in one go, the wizard failed with a skew many times beyond its limit, and one that changed widely from run to run (gantry squaring failing). Watching it, the owner saw the head stop short on the left, against the spring-loaded buttons of docks 1 and 2, while on the right it traveled all the way in, every time. Neither button felt stiffer than the one on dock 8, and nothing else was in the way. With docks 1 and 2 taken off, the wizard passed.

That fits how the wizard measures, described above: it takes wherever the head stalls as that dock's position, so anything that holds the head back on one side reads as skew. This is the page's reading of the 6.9.1 source alongside one owner's account; why the buttons stopped the head on that machine was not established, and whether anything similar played a part on the rotated-row machine is not known.

Another owner suggested checking that the plate the docks are mounted on sits flush at both ends, and swapping docks 1 and 8 to see whether the fault moves with the dock. The reporter did not say whether they tried either.

After the belts were retuned, the same machine went on to fail the homing calibration with an early endstop trigger, a separate homing fault tracked in #5520. The owner cleared that by going back to 6.9.1-beta. That release predates the squareness wizard, so the downgrade settled the homing fault but says nothing about the wizard's reading. On 25 October 2026 #5520 was still open. Two owners there reported the same homing fault on 7.0.0, two more affected owners posted logs from 7.0.1, one of them saying the fault remains, and a later commenter reports it still present on 8.0.0, on two printers. The 7.0.1 and 8.0.0 release notes say nothing about homing. Another owner there reports dock calibration stalling on their printer, which has the homing fault too: on 6.9.2 they had hardly been able to get beyond the fourth dock, and after going back to 6.9.0, where the homing fault was milder but still present, they got through the dock step. They do not say that the homing fault caused the dock failures, and another commenter suspects that machine has more than the motor fault, since most owners with the fault seem to pass every calibration on 6.9.1-beta. That is one owner (provisional), and they do not say how the docks failed.

The first dock fails, nothing else obviously wrong

provisional — several owners, but all in one forum thread.

The same forum thread collects the advice owners gave and the fixes that worked:

  • During the manual step, the head should fully enclose the tool, with the two front faces flush, and you should keep holding it there through the first button press.
  • Nothing in the way: the fence sitting flush with the frame, the waste bin clear, and full travel available to the head.
  • Belts and homing. Another owner, describing what is likely the same calibration (they call it tool calibration), only got it to pass after more belt work and redoing the homing calibration. The slack-belt account above comes from this thread too.
  • The tuning tool. One owner says Prusa's belt-tuning app gives no target guidance for INDX belts, Gen 2 or otherwise, so tension ends up set by trial; another found the app worked on the original belts but was unsure its targets suit the newer ones.

One owner posted on 30 September 2026 that five attempts at retuning the belts, realigning the gantry and rerunning the homing calibration had not brought the first dock's Y into range. They do not say whether they checked the belt setting raised earlier in the same thread, and they have not posted since.

The next posts, on 11 October 2026, describe a slower way to tighten. An owner whose dock calibration had gone wrong across the board, after a tool got stuck and homing kept failing, tightened both belt tensioners a little at a time, rerunning dock calibration on a single tool after each step until it passed. They caution that the answer might instead lie in loosening, and warn against over-tightening. A second owner then got all eight docks through the same way. Neither describes a failure confined to the first dock: the first had every dock off (compare the slack-belt account above, though they give no direction or amount), and the second does not say how theirs failed, so this does not show that a lone failing first dock yields to the same treatment. That is a way of searching for a tension, not a target for one, and it is still one thread: provisional. Prusa's belt-tension guide remains the reference, and since tension feeds into the other calibrations, rerunning them from the start once the docks pass is this page's suggestion; neither owner says whether they did.

TODO(verify): the size of each tightening step and the total tensioner rotation one owner needed, from the toolhead docking calibration thread. Withheld as a tensioning setting.

What to do

Just flashed the INDX firmware? On a machine without the Gen 2 belts, check the 1.5GT Belts setting before running any calibration.

Read the numbers before changing anything. The failure screen shows the measured and expected position of the dock it rejected. Note which docks fail and how far off each one is in X and in Y. The pattern points to the cause far better than any single reading.

Docks out by the same amount in Y, or the wizard stopped at the first dock with a Y error: check the belt setting first. It costs nothing, and it is the only cause on this page with two confirmed fixes behind it. Identify the belts first, by counting teeth as above. Then set the 1.5GT Belts toggle itself to match them; choose a printer variant only if every part of that edition matches what is fitted. Rerun the calibrations from the start, since the change resets several of them. If the setting was already right, belt tension is next.

Error growing along the row: check squareness. On 6.9.1 or 6.9.2, run the gantry squareness wizard, with the nozzles taken out of docks 1 and 8 as it asks. None of the 7.0.0, 7.0.1 or 8.0.0 release notes mention the wizard, and none of those releases' source is public yet, so this page has not confirmed that it behaves the same on them. The INDX handbook revision of 22 October 2026, on the same downloads page, lists the wizard among its additions, so Prusa now documents it. One owner reports it crashing to an internal error on 7.0.x (provisional, see Verification). If the wizard reports significant skew, square the gantry by the guide first and treat the dock failure as most likely a symptom of that. Because the wizard measures against those same docks, it is not an independent check on them; if squaring the gantry by the guide will not satisfy it, tell support that, along with the dock values. If the skew it reports is implausibly large, or jumps between runs, watch where the head stops at each end before touching the gantry: on one machine the dock buttons were stopping it short (provisional, see above).

Neither pattern: work through belt tension, gantry squareness and homing calibration, then rerun the calibrations from the start rather than retrying the dock step alone.

Still stuck: contact support with the measured values for every dock. See who to contact.

Verification

reported for the belt-type cause: two owners, in two unrelated places — a firmware bug report and a forum thread — each fixed a dock calibration stuck on a large, unchanging Y error by changing the belt or Gen 2 configuration to match the hardware. In the bug report a Prusa developer identified the cause before the owner confirmed it.

First-party. How the firmware validates a dock — fixed expected positions, one shared Y on the Core One, a fixed window, and what happens to a dock that falls outside it — comes from Prusa's public firmware source, read at the 6.9.1 release tag. The tie between printer variant and belt setting, the Gen2 variant as the default on first run and after a factory reset that clears the hardware configuration, and the calibrations a belt-setting change resets come from the same source, as do how the gantry squareness wizard measures and the limit it passes against. Firmware 6.9.2, released on 7 October 2026, adds the PVA and BVOH filament presets to 6.9.1 and nothing else that reaches an INDX (compare), so everything read here at the 6.9.1 tag holds for it unchanged. Firmware 7.0.0, published on 15 October 2026, says nothing about dock calibration, the belt setting or the squareness wizard in its release notes. Prusa has not yet published its source, so this page cannot confirm that what was read at 6.9.1 still holds on 7.0.0. Firmware 7.0.1, published on 19 October 2026, lists a single fix, for a hang at startup, and touches none of this. Firmware 8.0.0, dated 22 October 2026, mentions dock calibration in its notes only to say that the head now approaches the dock more gently, and says nothing about the expected positions, the window, the belt setting or the squareness wizard. Neither release's source is public, so the same caveat applies to both. The INDX handbook revision posted on the same page and day as 8.0.0 lists the squareness wizard among its additions. The squareness wizard is absent from the 6.9.1-beta source, which is why a downgrade to that release cannot speak to it. The warning text for the belt setting is the printer's own. An earlier request (#5445) to validate docks against a reference measured on the machine was closed as not planned. Relaying the team's view, the developer judged it a large job for a small gain at the current stage of development, while not dismissing the idea, once the belt setting had explained the original case.

provisional: the rotated-row case is one machine; the owner reports being unable to square the gantry by the guide without breaking gantry calibration, support has not yet resolved it, and the developer's follow-up questions are unanswered. The squareness wizard held back by the dock buttons is one owner in one thread, and the dock step that could hardly get beyond the fourth dock alongside the homing fault is one owner on

5520. The wizard crashing on 7.0.x is one owner in

another forum thread: after updating to 7.0.0 or 7.0.1, which they name together, they saw the squareness test stop on an internal error screen once the head reached tool 8's position, and they say they are going back to 6.9.2. Whether it happens on other machines or on 8.0.0 is not known. The belt-tension and homing advice comes from several owners, but all in one thread, including the two who tightened in steps until the docks passed, and the slack-belt fix for a uniform shift is a single owner's account.

Still unverified: whether flashing the INDX firmware counts as the first run that applies the Gen2 default, which would explain both owners who found their printer set for Gen 2; whether docks 1 and 8 were empty in the owner's wizard runs; whether the skew the wizard reports on the rotated-row machine lies in the gantry or in the dock row itself; why the dock buttons stopped the head short on the machine whose wizard passed only with docks 1 and 2 removed; what the gentler dock approach in 8.0.0 changes, and whether it alters which docks pass; and whether any Core One left the factory with a dock row far enough out of line that no squaring brings it inside the window.