Issues¶
Known faults on the INDX, what causes them, and what has actually fixed them.
Pages here lead with the mechanism rather than the fix. That is deliberate: several INDX faults look alike from the outside and have completely different causes, and a reader who understands why a symptom happens can tell their fault apart from the one that merely resembles it.
How to read a page here¶
Check the confidence field before acting. A provisional page is one person's
experience written down so the next person recognizes it — not a procedure.
Where a page withholds a number behind a TODO(verify) marker, that is intentional.
Thresholds, temperatures, dimensions and deadlines are verified against hardware or
against the vendor before they are published here, because a wrong one costs the
reader a part, a print, or a warranty window.
Start with the symptom¶
The machine damages the print, or itself
- Toolhead collides with finished parts — slicing with Complete individual objects with more than one tool in use can drive the head through parts it has already finished. Open and unfixed on Prusa's toolchangers since March 2025. Turn the feature off.
The printer disagrees with reality about which tool is where
- Phantom tools, "tool not detected" and park failures — a tool that isn't there is reported present, a tool that is there is reported missing, or a tool that parked correctly is reported still attached.
- Tool unlocks or ejects from the head — the tool physically comes loose, often on the retraction after a filament load; one owner traced it to a defective gear in the lock. Also covers the reverse, a tool that stays locked in the head at its dock.
Probing or calibration fails
- Probing fails or nozzle never touches the bed — electrical interference in the loadcell signal makes the printer believe it has touched down while the nozzle is still well clear.
- Tool offset calibration error codes — which step of the calibration failed, for each code, and how to read it from the serial log when the printer only ever shows 36130. Start here for any tool offset calibration failure.
- Tool offset calibration fails — the contactless offset sensor returns no samples, so calibration has nothing to work with. Usually the sensor board.
- Tool offset calibration fails with a clean nozzle and nothing loaded — the bed is out of alignment in Z and gives way under the nozzle during the Z touch. Run Z Alignment Calibration before suspecting the board. Single source.
- Dock calibration rejects some or all docks — the measured docks fall outside the window the firmware expects. Which docks fail, and in which direction, points to the cause; docks all off by the same amount in Y usually mean the belt-type setting does not match the belts.
- Input shaper calibration stops with "Measurement failed" — the first axis measurement fails right after the accelerometer calibrates, mostly on 6.9.x; for one owner the accelerometer calibration itself now fails. Check the belt-type setting; no cause found yet. Single source.
- Oozing spoils bed probing and tool calibration — material where the machine is trying to take a measurement. Start by cleaning the offset sensor window.
Defects appear on the printed part
- Blobs dragged into the print — nozzle wiper and purge — material carried out of the purge area at tool changes. Largely addressed by firmware 6.9.0, which automated the wiper alignment that used to be done by hand.
- Diagonal banding across print walls — a regular pattern that reverses with perimeter direction. There is a two-print test that tells you whether it is the extruder or the motion system, before you open a support case.
Nozzles and the filament path
- Nozzle hardness and abrasive filaments — the shipped nozzles are not hardened in the conventional sense. What that means for filled filaments, and the vendor's remediation offer.
- Unload and eject failures — printing works but unloading fails. Single source — read the caveat before acting.
- Only one nozzle size has a slicer profile — the slicer offers the INDX a single nozzle variant, so other sizes cannot be selected at all. Worth knowing before buying nozzles, or taking store credit for them.
Process
- Who to contact — diagnosis and replacement parts come from two different companies, and sending your problem to the wrong one is the most common way owners lose weeks.
Arrived here with an error code?¶
The 361xx block is the toolchanger family. These are the codes that map onto a page:
| Code | On screen | Page |
|---|---|---|
36121 36122 |
Unknown nozzle | Nozzle hardness |
36123 |
Occupied dock | Tool detection |
36124 |
Tool lost | Tool detection |
36125 |
Tool pickup failed | Tool detection |
36127 |
Tool park failed | Tool detection |
36128 |
Retry tool park | Tool detection |
36130 |
Tool offset failed | Error codes to find which step failed, then tool offset calibration, or bed alignment with a clean nozzle and nothing loaded |
36190 to 36197 |
The step of tool offset calibration that failed | Error codes |
36135 |
Toolchanger error | Tool detection |
36136 |
Calibrate dock from menu | Dock calibration |
36202 |
Hotend preheat error | Tool detection |
36526 36527 36528 |
Loadcell measure failed / bad configuration / timeout | Loadcell noise |
Prusa publishes an article for every code, linked from each page. Around 104 distinct INDX codes exist; the ones above are those this knowledge base has something to add to. For anything else, Prusa's own article is the better answer. The exception is 36190 to 36197: they exist only in firmware built from hyiger/Prusa-Firmware-Buddy, and the QR code on those screens links to this knowledge base.
Three faults that look alike¶
Probing and calibration failures are the ones people misdiagnose most, because three unrelated causes present through the same two error paths. The quickest discriminators:
| What you see | Likely page |
|---|---|
| Probing stops with the nozzle visibly nowhere near the sheet | Loadcell noise |
| Bed probing is fine, but tool offset calibration fails | Offset sensor |
| Tool offset calibration fails on a clean, unloaded machine, on a different tool each run | Bed alignment |
| Material is building on the nozzle, deposits left on the sheet | Oozing |
| Failures follow a firmware update rather than appearing gradually | Tool detection |
Chasing the wrong one of these costs days, which is why each page opens by saying how to tell it apart from its neighbors.