Skip to content

Blobs dragged into the print — nozzle wiper and purge

Update to 6.9.0 or later before doing anything else

Firmware 6.9.0 introduced automatic calibration of the nozzle cleaner — this is confirmed in Prusa's own release notes, not just inferred from owner reports. The same release moved the purge point in Y and made the nozzle reheat in the cleaner when a print resumes. Owners additionally describe a revised wiping path and changed purge amounts. In the firmware source, "automatic" means the cleaner's position in X and Y, which the loadcell finds by touching it. The height of the silicone is still set by hand with a screw — see the warning under Deeper than you would think.

Three owners independently report the difference as dramatic — clean tool changes across mixed-material prints, one no longer needing a brim to catch debris on the first layer, and — most tellingly — the owner who opened the original complaint thread reporting that 6.9.0 has largely settled both the oozing and the cleaning. That did not hold for good. Weeks later the same owner, still on 6.9.0, had a print fail on a different filament and then could not get tool calibration to pass, which was new for them; after resetting the machine and recalibrating every tool, they had the oozing back as well. They then reported every calibration passing on a 6.9.1 build, without making clear which one; Prusa's 6.9.1 was at that point out only as a beta. See tool offset calibration.

Most of the manual procedure below exists because that calibration used to be done by hand, badly, with no way to see what you were doing. If you are on anything older than 6.9.0, update and re-test before investing any time in manual alignment. Height is the exception: it is still a manual step in 6.9.0, 6.9.1 and 6.9.2, and neither the 7.0.0 nor the 8.0.0 notes say that has changed.

The stable 6.9.1 notes name no change to the wiper or the purge. The beta did one thing for the cleaner: where appropriate, the bed now moves down during Nozzle Cleaner calibration, leaving room for a hand or a wrench. The stable notes do not repeat it, but the stable is built on the beta: in the firmware repository it adds 15 commits to the beta tag, none of them about the nozzle cleaner. That comes from the release history, not from the notes. 6.9.2, released 2026-10-07, leaves all of this as it was: it is 6.9.1 plus the PVA and BVOH filament presets that the 6.9.1 notes announced but left out, and nothing else that reaches an INDX (compare).

Firmware 7.0.0, dated 15 October 2026 on Prusa's downloads page, has two lines on the cleaner. One promises improved nozzle wiper cleaning without saying what changed; the notes tag it as already shipped in 6.10.1, which was firmware for the XL and XL+, not for the INDX. The other moves filament loading and unloading to positions that take account of the calibrated cleaner offset. Prusa had not published the 7.0.0 source when this was written. One INDX owner has since reported on the wipe under 7.0.0, and for PETG they find it worse than under 6.9.0, not better (see Residue left by the clean before calibration below). That is a single report, and whether either line settles anything else on this page is open.

Firmware 8.0.0, dated 22 October 2026 on the same page, has two lines that come near the cleaner. Flexible filaments are now slowed down less while the nozzle is cleaned. And the bed drops further during calibrations that need a hand inside the printer, which reads as a continuation of the 6.9.1 beta change above; the notes do not say which calibrations those are. Nothing in them touches wiper height, the cleaning temperature, the order of purge, cool-down and wipe, or the amount purged. Prusa has not published the 8.0.0 source either, and no INDX owner has yet reported how the wipe behaves on it.

Several owners have found material still on the nozzle after the clean that runs as a print begins, mostly PETG, and one finds it more often on 6.9.2 and 7.0.0 than on 6.9.0. They put it down variously to the order of that clean and to its temperature. That is set out under Residue left by the clean before calibration below.

Summary

On firmware before 6.9.0, the most common INDX print-quality complaint was filament being dragged out of the purge area and deposited on the print — blobs, zits and strings appearing at the start of a print and at tool changes. The cause is usually not the filament: it is where the nozzle sits relative to the silicone wiper block when it purges. Sitting in the purge material rather than clear of it is what lets a blob stick to the nozzle and ride out onto the part.

Detail

What is actually happening

At a tool change the head purges into the bin, then retreats past the silicone block at the front on its way to the part. Owners consistently describe the same sequence: the purge happens, the nozzle drags some of it along on the way back, sits in it briefly, and then carries it onto the sheet. It shows up on the first tool of a print and again at subsequent changes.

It is material-dependent in a way that rules out a single simple cause. PLA prints often come through clean while PETG and ABS do not. Ooze explains the PETG case plausibly, but one owner specifically noted ABS blobbing too, which ooze alone does not account for — stickiness of the purge material against the nozzle wall matters as much as how much oozes.

Read the pellets — this is the best diagnostic on this page

The shape of the discarded purge material tells you where you are, with no measurement required:

  • Compact, rice-grain pellets — the classic "good" result.
  • Long worms, tadpoles, or strands stuck together — the purge is stretching rather than breaking cleanly.

A small change in the Y position flips between these two outcomes. That sensitivity is the single most useful thing to know before you start adjusting, because it means you are looking for a narrow window, not a broad one.

TODO(verify): the Y adjustment magnitude that one owner reported as the difference between rice grains and worms. It is a small fraction of a millimeter and it is machine-specific, so it is withheld here rather than published as a target.

Which pellet shape is actually better is disputed

The community knowledge base recorded the 6.6.2-era shift from compact pellets to stringy tails as a regression. An owner in the forum thread later argued the opposite — that worms may have been deliberate, because a worm keeps the nozzle from nestling into the top of a blob, detaches more readily, and does less damage if it does reach the print. Both readings are in the sources. A later report adds a data point without settling it: the same owner cited in the warning box below found their purge coming out as worms joined end to end, some of which landed on the bed. Treat pellet shape as a sensitive indicator that your alignment changed, which it certainly is, rather than as a target to optimize toward.

The real difficulty is that you cannot see it

Owners are unanimous that the hard part is visibility, not judgment. The wiper sits where you cannot get eyes on it during a purge, and people resorted to dentists' mirrors. Two techniques circulate:

  • Backlight it. Put a light source behind the bin and adjust until the light just disappears behind the nozzle. This gives a repeatable visual reference where direct observation gives none.
  • Adjust during a print. From 6.6.3 onward there is a Nozzle Cleaner Y Offset item in the printer's Tune menu, reachable while a print is running, so you can change position and immediately see the effect on the next pellet. Earlier firmware exposed X and Y cleaning offsets the same way. Note that these are only reachable mid-print, which is deliberate — you need a running print to have anything to judge.

TODO(verify): the direction and magnitude of a useful Nozzle Cleaner Y Offset. This one is genuinely per-machine — the community knowledge base records owners reporting success with offsets in opposite directions, so there is no correct value to publish. Establish your own from the pellet shape.

Deeper than you would think

The most useful pre-6.9.0 finding, and the one with the clearest first-hand confirmation, concerns Z rather than Y. The working position is deep — the nozzle genuinely down in the silicone rather than lightly grazing it.

One owner reasoned that burying the nozzle in the silicone would seal it and prevent a final blob forming, tested it, and reported back that doing so completely cured their ABS blobbing — on the opening tool and on every later change alike. The community knowledge base independently records a systematic height test reaching the same conclusion: the working position is deeper than the light-contact rule of thumb people assume.

If you are calibrating by hand, err deep rather than shallow.

TODO(verify): the nominal gap figure that this finding contradicts, and any measured depth. Neither is published here — the actionable form is directional ("deeper than just touching"), which needs no number.

An open question about the automatic calibration

Before 6.9.0 shipped, an owner raised the concern that if an automated routine calibrates to just touching, it might reinstate exactly the blobbing that burying the nozzle cured. Early reports on 6.9.0 are good and do not show this, but nobody has confirmed what depth the automatic routine actually targets. If you update and blobbing returns having previously been fixed by going deep, this is the first thing to suspect.

The firmware source narrows the question. The automatic part of the Nozzle Cleaner Calibration wizard measures where the cleaner sits in X and Y; it does not set the depth. Height is a one-time manual step in the same wizard, which asks you to rest the nozzle in the center of the silicone V-groove and then shows: "Turn the adjustment screw counterclockwise until it touches the silicone." The wizard's own steps are the same in 6.9.0 and 6.9.1, so on both the depth is whatever that screw step leaves, and the criterion the wizard states is contact, not burial. That is a reading of the code; nobody has reported comparing the result against the deeper setting on hardware, so the question stays open.

It matters because owners can read the 6.9.0 notes as meaning the cleaner now sets itself up entirely. One owner who mentioned 6.9.0, whose purge was not coming out as rice grains and was filling the bin fast, assumed just that and said calibration no longer asked about the wiper; a reply told them to raise the wiper pad with its screw (thread). The reply was unsure which way to turn it, and the direction it guessed does not obviously match the wizard's; go by the wizard and watch the block move. The owner has not reported back, and whether every setup path runs the wizard is not established.

One later owner, firmware not stated, reports trouble from too little contact. Primed material was clinging to the back of their nozzle and dropping onto the bed mid-print; after they adjusted the wiper height until it definitely touched the nozzle, the priming at least went well, and each recalibration of the wiper left them with a different purge. Their wiper had not been reliably touching, which is not the same as one set to just touching, so this is a single report that more contact helps. It says nothing about whether the automatic routine stops short.

A further owner, writing in mid-October on firmware they do not state but before they moved to 7.0.0, says their early stringing and blobs eased a great deal once they set the height so that the nozzle presses well down into the pad (thread). They also gave the earlier reply above about raising the pad, so this is not an independent second voice for it. A week later the same owner wrote that they had reset the pad well upward, as high as it would go, so that silicone surrounds the nozzle, and that a six-color PLA print in undried filament of several brands, on the generic profile, then came out with next to no stringing (thread). They are not sure the pad was the whole story, say the setting is judged by eye with no scale to read, and ask why the loadcell does not set it. That thread names no firmware; in the earlier thread they had said on 16 October that they had just installed 7.0.0. provisional — one owner across two threads, directional only, and like the last one it does not show whether the automatic routine stops short.

Workarounds that do not involve calibration

  • Print a skirt or brim. Several owners report this catching the initial debris before it reaches the part. It is the cheapest mitigation and it worked for the owner who started the main thread. One notes brims can be awkward to remove from the sheet.
  • Use a wipe tower instead of the purge bin. The tool-change G-code branches on whether a wipe tower is in use, so a wipe tower bypasses the purge-station sequence entirely. An owner reprinted a blob-spoiled ABS job with a minimal wipe tower and reported it came out very clean, for a small increase in print time.

    The trade-off is material-dependent, and worth getting right: a wipe tower is good for multiple colors of the same material, where the aim is only to stabilize flow. For dissimilar materials that do not bond to each other, the purge bin has the clear advantage, because a tower built from materials that will not stick together falls apart.

    TODO(verify): the reduced purge volume used for the minimal wipe tower, and the default it was reduced from. These are slicer settings and are withheld.

  • Add periodic wipes for single-nozzle prints and sticky filaments.

Residue left by the clean before calibration

Tool offset calibration runs as a print begins, and before it measures a tool it cleans that tool's nozzle. In the firmware source the clean purges hot, cools with the part fan on, then gives the nozzle its full wipe (see Verification). Whatever survives that wipe is still on the nozzle when it is measured.

On a 6.9.1 build, one owner found PLA drawn out into long strings and left clinging to the nozzle, after which nozzle probing failed; going back to 6.9.0 seemed better, though they suspected their own wiper setting or a load cell fault. A second owner, on the beta, found PETG left on the nozzle after the wipe, enough to fail bed leveling, while crediting the beta with fixing most of their PETG calibration trouble. Both are single reports.

An upstream report against the beta, also with PETG, blames the order of that clean (#5505): the nozzle is cooled after its purge and before its main wipe, so the purge has time to firm up and is not fully cleared, and calibration then fails on what is left. The reporter asks for the wipe to come before the cool-down. The firmware source does run that sequence, and the order is the same in 6.9.0. What the beta changed is how far the nozzle cools before that wipe: its notes lower the tool offset calibration temperature, and the source applies that to this cool-down; stable 6.9.1 keeps it.

Whether that left more residue, or made the same residue matter more, is not settled. One INDX owner now says both; theirs is a single report, filed in October against 6.9.2 and 7.0.0 (#5567). With PETG and the stock start G-code, they found PETG left on the nozzle ahead of probing now and then on 6.9.0 but often on 6.9.2 and 7.0.0, and on 7.0.0 photographed a large lump of hardened PETG on the tip and side of the nozzle right after the cleaning routine. Going back to 6.9.0 cut the problem a good deal without ending it. Their explanation is that at the lower calibration temperature any leftover PETG is fully solid, so it throws the measurement off further, and the Z offset comes out too high. That is one owner's comparison on one machine, not a controlled test, and the explanation is theirs.

A different owner, commenting on a separate issue (#5500), objects to the same order as #5505: the nozzle should not sit in its purge while it cools, but be cleaned as it cools, because by the time the wipe comes the material has set on the tip. So the complaint about the order rests on two reports in two issues. It has not been checked whether the #5505 reporter is independent of the PETG account above, and whether wiping first would help is untested.

Others come at it from the temperature side. In October a forum owner observed that the automatic clean runs far below printing temperature, too cool in their view to soften PETG enough to wipe it off, and suggested running it at the temperature of the loaded material instead (thread). The same owner then filed that suggestion upstream as an enhancement request (#5568), so the thread and the request are one voice, not two. Neither the thread nor the request says which firmware the owner is running. In the request they describe what they see the printer do: heat to printing temperature, purge, move off, cool, then brush the nozzle in several directions, which matches the source reading. They say that with sticky materials such as PETG and PCTG, bits stay on the tip and come loose onto the print once the nozzle is back at printing temperature, as lumps. They ask for a cleaning temperature that follows the loaded material, or failing that a menu setting, and they add in the thread that PETG did not always come off even at the warmer temperature earlier firmware cleaned at. The #5567 reporter, separately, lists cleaning hotter as one possible fix, beside cleaning the nozzle before the calibration and a calibration temperature that follows the filament. One commenter on #5568 disagrees: the material should be soft, not runny, and the lower temperature is closer to what they would choose.

So the residue itself is now reported: two owners in separate reports find the cool clean leaves sticky PETG behind, and the two complaints about the order describe the same thing. The causes they offer are not established. That a hotter clean would cure it is a proposal nobody has tested, and one commenter argues against it. Neither the 7.0.0 nor the 8.0.0 notes list a change to the cleaning temperature or to the order.

TODO(verify): the calibration and cleaning temperatures before and after 6.9.1, and the hotter cleaning temperatures proposed in #5567, #5568 and the forum thread. None of them is published here.

The #5567 reporter also points out that Prusa's start G-code runs the tool offset calibration ahead of the print's own nozzle clean, and suggests cleaning first. The start G-code this site reproduces has that order: G427 comes ahead of bed leveling and of the G12 cleaning-station lines that prime the first tool (see annotated profile G-code). The calibration's own per-tool clean, described above, still runs inside G427; the request is for a further clean ahead of it.

The reporter of #5500 adds that 6.9.0 and 6.9.1 both purge more than they need to, often leaving material on the nozzle after the wipe, and that the firmware takes no notice of the slicer's purge volume. That is a single report, not checked against the source. Two later commenters there say they have the same issue, one on a four-tool Gen 2 and one who finds ASA sticks worse still, without saying which of its complaints they mean, so it stays a single report. Whether the improved wiper cleaning in 7.0.0 changes the order, the cool-down or the amount purged, its notes do not say, and the 8.0.0 notes touch none of the three. For probing failures in general, see oozing during probing and calibration.

Before you blame the wiper

  • Rule out oozing and probing faults first. If material is accumulating during probing rather than at tool changes, see oozing during probing and calibration.
  • Check the silicone block is firmly mounted. If it shifts slightly during cleaning, no amount of calibration will stay consistent.
  • If results are inconsistent between tools, suspect tool offsets rather than the wiper — tools that come to rest at marginally different points with respect to the block produce exactly that symptom. See tool offset calibration.
  • Dry the filament. The INDX is reported to be more moisture-sensitive than the Nextruder it replaces.
  • A lone blob where a print resumed has a different cause. One owner on 6.6.3 traced blobs after a spool join to the nozzle oozing while the bed traveled back to printing height, and reported it upstream (#5391). The report was closed automatically for inactivity in late September 2026, with no reply from Prusa on it, so its closure says nothing about a fix. The same owner raised the same problem for an ordinary pause and resume, also on 6.6.3, asking for the purge and wipe to come after the bed is back in place (#5412). 6.9.0 now reheats the nozzle in the cleaner on resume. A second owner, filing after 6.9.0 was out (#5477), describes a resume that picks the tool and primes it over the silicone first and raises the bed only afterwards, so the primed nozzle oozes during that wait and the blob ends up on the part. They give no firmware version, so whether the 6.9.0 reheat helps is still not established. They ask for the bed to go up before the tool is picked and primed, and two more owners have added that they get blobs after a pause as well. In early October #5412 was flagged as stale, the same automatic step that preceded the closure of #5391; one of those two owners replied that it still affects them, and the flag was lifted. Both requests remain open with no reply from Prusa, and neither the 7.0.0 nor the 8.0.0 notes list a change to that sequence: the nearest 7.0.0 items fix an extra blob when resuming after a power failure, tagged as already in 6.9.0, resuming with a cold tool after a filament change on another tool, and a Z shift after a Spool Join on an instant runout. None of them changes the order of bed travel, pick and prime that #5412 and #5477 ask about. No workaround is confirmed: one commenter suggested a small wipe tower for jobs with a pause, but had not tried it. reported — two owners, in separate issues, trace the blob to ooze while the bed travels.

Temperatures, retraction and flow

Community consensus is that several stock profile values are not well suited to this toolhead's high-flow nozzle geometry, which transfers heat more efficiently than what many owners are coming from — so the general direction is cooler rather than hotter, with retraction figures that are strongly machine-specific.

No values appear on this page. Every temperature, retraction distance, extrusion multiplier and pressure-advance figure discussed in the sources is withheld pending verification on hardware.

TODO(verify): stock versus community-preferred temperature ranges per material; retraction ranges and the profile defaults they depart from; the reduced extrusion multiplier reported for at least one filled material; and the per-nozzle-diameter pressure advance table that circulates as a start-G-code snippet. These are exactly the numbers that damage a stranger's printer when wrong, and they are the reason this section is deliberately empty.

Verification

reported — multiple independent owners, across two dedicated threads, over roughly two months of firmware changes, with the firmware behavior itself confirmed first-party.

The 6.9.0 changes are documented in Prusa's own release notes, which name the automatic nozzle cleaner calibration, the shift in purge point, and the nozzle reheat on resume. That upgrades the headline claim on this page from owner inference to vendor-documented fact.

The primary source is Nozzle cleaning/calibration issues, an 87-post thread with sixteen participants running from late July to mid-September 2026. It contains the symptom reports, the visibility complaints, the Tune-menu adjustments, the wipe-tower experiment, the 6.9.0 outcome, and the later single reports on wiper height and on 6.9.1. Much of its later traffic is about tool offset calibration, which belongs to its own page.

The 6.9.1 re-check: the stable notes list a gantry squaring wizard and a homing fix, and neither touches the cleaner. The bed dropping during Nozzle Cleaner calibration comes from the beta notes only. Nothing on this page is contradicted by either. The 6.9.2 release adds the PVA and BVOH presets and nothing else that reaches an INDX; none of the source files cited below differs between the v6.9.1 and v6.9.2 tags, so the reading that follows holds for 6.9.2 as well.

The 7.0.0 re-check rests on the notes alone: Prusa had published no 7.0.0 tag on GitHub when this was written, so the source reading below stops at 6.9.2. Of the two cleaner items described in the tip, neither says what changed in the wipe, and the notes name no change to wiper height, to the order of purge, cool-down and wipe, or to the order of bed travel and priming on resume that #5412 and #5477 ask for. One INDX owner has since reported PETG left on the nozzle after the wipe on 7.0.0 (#5567); nobody has reported on the amount purged there.

Firmware 7.0.1, published on 19 October 2026 on the same downloads page, lists a single fix, for a hang at startup, and touches nothing on this page.

The 8.0.0 re-check also rests on the notes alone, since there is no 8.0.0 tag on GitHub either. Its two lines near the cleaner, flexible filaments slowed down less during cleaning and the bed lowered further for calibrations that need a hand inside, are described in the tip. Neither names a change to wiper height, to the cleaning temperature, to the order of purge, cool-down and wipe, or to the resume order.

What the automatic calibration does and does not cover, and the order of purge, cool-down and wipe in the per-tool clean that runs as a print begins, are read from the firmware source at the v6.9.1 tag: the calibration routine, its screens, the tool offset calibration that runs the clean, and the cleaner's sequences. The wizard's own steps, the screw step among them, and the cleaner's wipe and purge moves are unchanged from the 6.9.0 tag. The lower bed during the wizard that the beta notes mention comes from a calibration preamble the wizard shares with other calibrations, not from the wizard itself. The tool offset calibration did change: the beta lowered the temperature the per-tool clean cools to before its main wipe, which is one of the two calibration temperatures its notes lower; the other is for the XY scan. The source shows what the firmware does, not how well the result works on any one machine.

The 6.9.0 improvement is independently confirmed by three owners: one reports clean tool changes on a mixed TPU/PETG print and again on a four-color PETG print; a second separately reports the result is much cleaner and that they no longer need a brim to catch debris; and the owner who started the thread — the person with the worst of the problem — has since confirmed that 6.9.0 has mostly resolved the oozing and cleaning for them. The last of those is the strongest single data point on this page, because it is the original complainant closing their own report. That is the strongest claim on this page. It carries one qualification, set out in the tip at the top: weeks later, after a failed print, the same owner hit tool calibration failures on 6.9.0 that were new to them, and saw the oozing return once they had reset the machine and recalibrated every tool.

The "bury the nozzle" finding comes from Nozzle wiper vs. INDX offset sensor, where an owner states the hypothesis, tests it, and reports the confirmed result in the same thread — hypothesis and outcome from the same person, which is weaker than two independent reports but stronger than an unbacked assertion. The common problems summary records a separate systematic height test reaching the same conclusion.

Where the sources disagree: whether the change in pellet shape was a regression or an intentional improvement, as noted in the body. The sources are directly in tension and neither is confirmed.

Explicitly not carried onto this page: a claim in the thread that the wipe-tower minimum purge setting also governs purge-bin volume despite its name. The owner who posted it said plainly that they had traced it with an AI assistant rather than reading the firmware, and told readers to take it with a pinch of salt. It is recorded here as a lead for someone to verify, not as guidance.

Also not carried over: a dynamic overhang-fan profile issue described in the community knowledge base. It appears in no other thread in the forum corpus, and it is a cooling problem rather than a wiper one — it belongs on its own page, at provisional, if someone can corroborate it.

Nor is an upstream report that the firmware's wipe path consistently lands off-center in Y on the silicone pad (#5496). It reads like the Nozzle Cleaner Y Offset question above, but it was filed against a non-INDX Core One+ (Gen 2) with its own wiper accessory, on the non-INDX 6.8.1 firmware. A second owner has since confirmed it, again on a non-INDX Gen 2. Prusa developers took it up in October: the first to reply says that on that machine the wipe runs at a position set by hand in the firmware, and another asked the owners to check the printer's belt-type setting. After updating to 7.0.0 the reporter still found the wipe off-center. No INDX owner has reported the same there. The INDX, by contrast, measures where its cleaner sits (see the source reading above); that contrast is this page's reason, not the developers', for not carrying the report over. The report is not evidence of a systematic Y error on the INDX, and the per-machine reading of the Y offset stands.

Also not carried over is a later Gen 2 report in which the wipe runs in the air, well above the wiper (#5563), because it comes from machines that have no INDX or do not say they have one, and no INDX owner has reported it. Its reporter says the machine has no INDX. Two owners have since added that they see it too, both on 8.0.0 and both on a Gen 2: one names Prusa's wiper accessory and an MMU3, the other does not mention an INDX.