title: Tool offset calibration fails: bed not aligned in Z confidence: provisional updated: 2026-10-25 author: hyiger printer: Core One toolhead: INDX hotend: unknown nozzle: unknown firmware: 6.9.1-beta on the reported machine; the mechanism is not version-specific sources: - https://help.prusa3d.com/article/tool-offset-failed-36130-core-one-indx_1089016 - https://help.prusa3d.com/article/uneven-bed-31111-core-one-35111-core-one-l-36111-core-one-indx_856294 - https://github.com/prusa3d/Prusa-Firmware-Buddy/blob/v6.9.1-beta/src/common/probe_analysis.cpp - https://github.com/prusa3d/Prusa-Firmware-Buddy/blob/v6.9.1-beta/src/marlin_stubs/G162.cpp - https://github.com/prusa3d/Prusa-Firmware-Buddy/compare/v6.9.1-beta...v6.9.1 - https://github.com/prusa3d/Prusa-Firmware-Buddy/compare/v6.9.1...v6.9.2 - https://help.prusa3d.com/downloads/core-one-indx - https://github.com/prusa3d/Prusa-Firmware-Buddy/issues/5526 - https://github.com/prusa3d/Prusa-Firmware-Buddy/issues/5518 superseded_by:


Tool offset calibration fails: bed not aligned in Z

Summary

Tool offset calibration can fail with the same error code as a faulty offset sensor board on a machine where the nozzle tips are clean, the sensor is clean and no filament is loaded, because the bed is out of alignment in Z. One owner on 6.9.1-beta had calibration fail on a different tool from one run to the next, and a ferrite core on the toolhead cable changed nothing. The owner moved the bed to the bottom of its travel to reset its level, which is what Z Alignment Calibration does, and the failure went away. Z Alignment Calibration costs nothing and cannot make anything worse, so run it before you suspect the sensor board or the loadcell.

Error codes that lead here

Code What the printer shows
36130 Tool offset failed
36193 Probing the tool offset sensor failed

It is the same code as the offset sensor board fault. The on-screen message tells you to check that the nozzle is clean. If you have done that and nothing is loaded, this page is the next thing to rule out.

Firmware built from hyiger/Prusa-Firmware-Buddy reports a rejected touch on the sensor as 36193 instead, so there this fault no longer shares a code with the sensor board.

Detail

Tool offset calibration on the INDX takes two kinds of measurement. The contactless sensor reads the nozzle position in X and Y without touching it. The Z measurement is a physical touch: the bed rises until the nozzle rests on the sensor housing and the loadcell registers contact. On the Core One every Z move is a bed move, so that touch depends on the bed carriage traveling freely on its lead screws.

The firmware does not accept a touch on the strength of the contact alone. It holds position briefly after contact and checks that the measured force stays steady. If the force keeps changing while nothing is supposed to be moving, the sample is thrown out. In the serial log that shows as a probe classified as not OK, naming the feature angle_after with a negative value. The calibration retries a fixed number of times for each tool and then stops with the code above.

A bed carriage whose sides are out of step binds slightly on its guides. When the nozzle presses down on it, the binding carriage settles instead of holding still, so the force at the nozzle eases off after contact. That is exactly the pattern the check rejects. It also fits the failure moving between tools from one run to the next: each tool makes contact at a slightly different bed height, and a racked carriage does not bind the same way at every height.

What makes this fault easy to misread:

  • The nozzle is clean and nothing is loaded, so the ooze explanation does not apply and the on-screen advice leads nowhere.
  • It looks like interference. Failures that come and go, on different tools, on a machine that passes its loadcell selftest, are what a noise problem looks like from the outside, and on other machines noise has been the cause, see loadcell noise. The owner fitted a ferrite core on that theory. It made no difference. The tip below says how to tell the two apart.
  • It looks like a bad sensor board. The sensor board page describes calibration failing part way through the tool sequence with the stopping point moving between attempts. This presents the same way. The difference is in the log: a sensor board fault gets no sample at all, while this fault gets samples and rejects them.
  • Nothing in the normal flow points at the bed. The firmware offers Z Alignment Calibration on its own only when a bed leveling pass finds the surface out of plane by more than a fixed margin. A carriage that is racked by less than that prints acceptably and never triggers the offer, and tool offset calibration does not level the bed at all. 7.0.0, published on 15 October 2026, lists automatic Z-axis alignment on an uneven bed among its new features. Its notes do not say what triggers it, and its source is not yet published. If it takes the place of that offer, a carriage racked by less than the margin would presumably still be left alone. That is an inference. The notes for 7.0.1 and for 8.0.0, published on 19 and 22 October 2026, add nothing about it, and no owner has reported on the new behavior yet.

What to do

  1. Run Z Alignment Calibration, under Control, then Calibrations & tests. The procedure homes Z, drives the bed to the bottom of its travel and pushes a short distance past the hard stop, so that the Z drive skips against the frame until the carriage sits square. That is what resets the alignment. The owner described what they did as moving the bed to the bottom of the printer to reset the level, which is the step this procedure performs. Run it by hand on 7.0.0 and later too: nothing in their notes says the automatic alignment covers this case.
  2. Run tool offset calibration again. On the reported machine the failure was gone afterwards.
  3. If it still fails, the vendor's uneven bed article says to move the bed down, loosen the trapezoid nuts and check that they travel freely on the lead screws. After that, capture a serial log and go to the sensor board page.

Telling them apart

Several faults share this error code, and the serial log separates three of them. No sample at all points at the sensor board. Samples taken and rejected with angle_after mean something is giving way under the nozzle: filament on the tip, or the bed carriage. With the tips clean and nothing loaded, that leaves the carriage. Clean and unload before you read anything into the log, because ooze is rejected the same way. Noise on the loadcell gets touches rejected too, and this page has no log from stock firmware showing which check rejects them, so go by when and how it fails instead. In the reports on that page, noise fails the calibration at print start while it passes from the menu, and the nozzle can be seen stopping short. One owner on stock 6.9.2 ended the failures that rewiring had left by switching the bed's status light off from the menu (firmware issue 5526). Their latest summary, on firmware issue 5518, credits their complete fix to the rewiring, ferrite cores on the cables of the bed and chamber lights and a lower probing temperature in the start G-code. Switching the light off is not on that list, though they think the bed light's cable was the likeliest source, so their result does not show that switching it off is needed. A second owner on issue 5526, for whom ferrite beads did not help, reports that switching the light off has so far seemed to help every time. provisional, two owners on one issue.

Verification

provisional: one machine, one owner, and the report reached the author directly while helping with the diagnosis rather than through a public thread, so there is no link for the report itself. What is on record: on 6.9.1-beta, tool offset calibration failed repeatedly with the failing tool changing between runs, with clean nozzle tips, a clean sensor board and no filament loaded. The log showed touches being taken and rejected with angle_after. A ferrite core on the toolhead cable made no difference. After the owner moved the bed to the bottom of its travel to reset its level, the failure went away.

The mechanism above is the author's reading of the firmware's probe classifier against that log. It fits, but it has not been confirmed by the vendor or reproduced on another machine. The firmware references are the classifier in probe_analysis.cpp and the alignment procedure in G162.cpp, both at the 6.9.1-beta tag. Neither file changed in the stable 6.9.1 or in 6.9.2, which on the INDX changes only the filament presets, so the reading applies to both. Prusa has not yet published the source of 7.0.0, 7.0.1 or 8.0.0, so whether either file changed in them cannot be checked. The 7.0.0 notes list automatic Z-axis alignment on an uneven bed and say nothing about tool offset calibration; the notes for 7.0.1 and 8.0.0 mention neither. The status-light reports are from one owner on stock 6.9.2 and a second who does not give their firmware, both on firmware issue 5526; the first of them later summed up their complete fix on firmware issue 5518. The opener of issue 5526 also logged which check rejected the touches, but on firmware they had modified, so this page does not use it. What Z Alignment Calibration is for, and the menu path, are from the vendor's uneven bed article.

If your machine matches this and Z alignment fixes it, that second report is what moves this page to reported. See contributing.